The paper gives a survey of the upcoming use of X-ray computed tomography (CT) for dimensional quality control purposes: i.e. for traceable measurement of dimensions of technical (mechanical) components and for tolerance verification of such components. It describes the basic principles of CT metrology, putting emphasis on issues as accuracy, traceability to the unit of length (the meter) and measurement uncertainty. It provides a state of the art (anno 2011) and application examples, showing the aptitude of CT metrology to: (i) check internal dimensions that cannot be measured using traditional coordinate measuring machines and (ii) combine dimensional quality control with material quality control in one single quality inspection run.

Computed Tomography for Dimensional Metrology

CARMIGNATO, SIMONE;
2011

Abstract

The paper gives a survey of the upcoming use of X-ray computed tomography (CT) for dimensional quality control purposes: i.e. for traceable measurement of dimensions of technical (mechanical) components and for tolerance verification of such components. It describes the basic principles of CT metrology, putting emphasis on issues as accuracy, traceability to the unit of length (the meter) and measurement uncertainty. It provides a state of the art (anno 2011) and application examples, showing the aptitude of CT metrology to: (i) check internal dimensions that cannot be measured using traditional coordinate measuring machines and (ii) combine dimensional quality control with material quality control in one single quality inspection run.
2011
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/149350
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 569
  • ???jsp.display-item.citation.isi??? 419
social impact