Short amplicon autosomal short tandem repeat (Mini-STR) assay has proved to be a highly useful tool in forensic applications, especially for highly degraded DNA samples that typically result in partial profiles and total loss of information from regular STR amplicons. In this study two new quadruplex systems were designed to get nuclear DNA profile from degraded forensic casework samples. In order to obtain PCR products less than 120 bp in size, primer pairs of eight STR markers, included in available commercially multiplex PCR kits, were redesigned and assembled intwo PCR-multiplexes: D8S1179, D3S1358, TPOX, D16S539 and CSF1P0, TH01, D13S317, D5S818. After validation, these two Mini-STR quadruplex were employed in paternity testing case that involved DNA extraction from archival postmortem Bouin’s fluid-fixed paraffin-embedded tissue where commercial kit yielded low success. The results obtained with the present Mini-STR PCR-multiplexes proved clearly demonstrating their usefulness in analyzing degraded DNA samples.

Development of two new Mini-STR multiplex assay for typing archival Bouin's fluid-fixed paraffin-embedded tissues

CAENAZZO, LUCIANA;
2009

Abstract

Short amplicon autosomal short tandem repeat (Mini-STR) assay has proved to be a highly useful tool in forensic applications, especially for highly degraded DNA samples that typically result in partial profiles and total loss of information from regular STR amplicons. In this study two new quadruplex systems were designed to get nuclear DNA profile from degraded forensic casework samples. In order to obtain PCR products less than 120 bp in size, primer pairs of eight STR markers, included in available commercially multiplex PCR kits, were redesigned and assembled intwo PCR-multiplexes: D8S1179, D3S1358, TPOX, D16S539 and CSF1P0, TH01, D13S317, D5S818. After validation, these two Mini-STR quadruplex were employed in paternity testing case that involved DNA extraction from archival postmortem Bouin’s fluid-fixed paraffin-embedded tissue where commercial kit yielded low success. The results obtained with the present Mini-STR PCR-multiplexes proved clearly demonstrating their usefulness in analyzing degraded DNA samples.
2009
FORENSIC SCIENCE INTERNATIONAL: GENETICS
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2376876
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact