Electrospray ionization mass spectrometry (ESI-MS) is being increasingly employed in the study of metal–ligand equilibria in aqueous solution. In the present work, the ESI-MS spectral changes due to different settings of the following instrumental parameters are analyzed: the solution flow rate (FS), the nebulizer gas flow rate (FG), the sprayer potential (E), and the temperature of the entrance capillary (T). Twenty-eight spectra were obtained for each of six samples containing aluminum(III) and 2,3-dihydroxypyridine at various pH, in the absence or in the presence of a buffer and of sodium ions. Amongthe considered instrumental parameters, T produced the largest effects on the ionic intensities. FS and FG affected the ESI-MS spectra to a lower extent than T. In the investigated conditions E had the weakest effects on the spectra. The correlations observed between the ionic intensities and these instrumental parameters were interpreted considering the presence of three kinds of perturbations occurring in the ESI-MS ion source: formation of some dimers in the droplets, different transfer efficiencies from the droplets to the gas phase for different complexes (according to their surface activity), and subsequent partial thermal decomposition of the dimers and of one of the monomeric complexes in the gas phase. Our results show that the evaluation of the effects produced in the ESI-MS spectra by a change of instrumental parameters can allow to identify the perturbations occurring when metal–ligand solutions are studied by ESI-MS.

Metal-ligand solution equilibria studied by electrospray ionization mass spectrometry: effect of instrumental parameters

DI MARCO, VALERIO;BOMBI, GIUSEPPE GIORGIO;
2009

Abstract

Electrospray ionization mass spectrometry (ESI-MS) is being increasingly employed in the study of metal–ligand equilibria in aqueous solution. In the present work, the ESI-MS spectral changes due to different settings of the following instrumental parameters are analyzed: the solution flow rate (FS), the nebulizer gas flow rate (FG), the sprayer potential (E), and the temperature of the entrance capillary (T). Twenty-eight spectra were obtained for each of six samples containing aluminum(III) and 2,3-dihydroxypyridine at various pH, in the absence or in the presence of a buffer and of sodium ions. Amongthe considered instrumental parameters, T produced the largest effects on the ionic intensities. FS and FG affected the ESI-MS spectra to a lower extent than T. In the investigated conditions E had the weakest effects on the spectra. The correlations observed between the ionic intensities and these instrumental parameters were interpreted considering the presence of three kinds of perturbations occurring in the ESI-MS ion source: formation of some dimers in the droplets, different transfer efficiencies from the droplets to the gas phase for different complexes (according to their surface activity), and subsequent partial thermal decomposition of the dimers and of one of the monomeric complexes in the gas phase. Our results show that the evaluation of the effects produced in the ESI-MS spectra by a change of instrumental parameters can allow to identify the perturbations occurring when metal–ligand solutions are studied by ESI-MS.
2009
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2377471
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
social impact