The paper describes a methodology for the evaluation of the eddy current losses in the permanent magnet machines, The methodology doesnpsilat require the application of a FEM transient analysis but relies on the coupling of magnetostatic and sinusoidal eddy current FEM analysis sequences. Its main advantageous features are shorter calculation times in comparison with the FEM transient code, the evaluation of each harmonic loss component and the capability to take into account the variation of some geometric parameters.

PM losses evaluation by harmonic analysis of the magnetic vector potential perturbation

ANDRIOLLO, MAURO;MARTINELLI, GIOVANNI ATTILIO;MORINI, AUGUSTO;TORTELLA, ANDREA
2008

Abstract

The paper describes a methodology for the evaluation of the eddy current losses in the permanent magnet machines, The methodology doesnpsilat require the application of a FEM transient analysis but relies on the coupling of magnetostatic and sinusoidal eddy current FEM analysis sequences. Its main advantageous features are shorter calculation times in comparison with the FEM transient code, the evaluation of each harmonic loss component and the capability to take into account the variation of some geometric parameters.
2008
Proceedings of 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century
9781424419050
9781424419067
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2434344
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact