In this paper issues in the measurement of magnetic field in industrial environment are presented. Finite element simulations of the sensor readings in a non-uniform field are compared with real measurement values. Suggestions in order to improve the measurement accuracy using common three-axial non-centered probes are proposed. Indications about the better probe position with respect the field source are given.

Magnetic Field Measurement in Industrial Environment

BERTOCCO, MATTEO;SIENI, ELISABETTA;SONA, ALESSANDRO
2007

Abstract

In this paper issues in the measurement of magnetic field in industrial environment are presented. Finite element simulations of the sensor readings in a non-uniform field are compared with real measurement values. Suggestions in order to improve the measurement accuracy using common three-axial non-centered probes are proposed. Indications about the better probe position with respect the field source are given.
2007
Proceedings of Instrumentation and Measurement Technology Conference
9781424405886
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.