Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was used for the rapid detection of cocaine, benzoylecgonine and cocaethylene in hair. Different MALDI sample preparation procedures have been tested and the employment of a multi-layer 'graphite-sample-electrosprayed alpha-cyano-4-hydroxycinnamic acid (HCCA)' yielded the best results for standard solutions of the target analytes. The same approach was subsequently applied to hair samples that were known to contain cocaine, benzoylecgonine and cocaethylene, as determined by a classical GC-MS method. It was however necessary to extract hair samples by incubating them in methanol/trifluoroacetic acid for a short time (15 min) at 45 degrees C; 1 microl of the obtained supernatant was deposed on a metal surface treated with graphite, and HCCA was electrosprayed on it. This procedure successfully suppressed matrix peaks and was effective in detecting all the target analytes as their protonated species. The results obtained give further confirmation of the effectiveness of the MALDI for detecting drugs and their metabolites in complex biological matrices. The method can be useful as a fast screening procedure to detect the presence of cocaine and metabolites in hair samples.

A fast screening MALDI method for the detection of cocaine and its metabolites in hair

VOGLIARDI, SUSANNA;FAVRETTO, DONATA;FERRARA, SANTO;
2009

Abstract

Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was used for the rapid detection of cocaine, benzoylecgonine and cocaethylene in hair. Different MALDI sample preparation procedures have been tested and the employment of a multi-layer 'graphite-sample-electrosprayed alpha-cyano-4-hydroxycinnamic acid (HCCA)' yielded the best results for standard solutions of the target analytes. The same approach was subsequently applied to hair samples that were known to contain cocaine, benzoylecgonine and cocaethylene, as determined by a classical GC-MS method. It was however necessary to extract hair samples by incubating them in methanol/trifluoroacetic acid for a short time (15 min) at 45 degrees C; 1 microl of the obtained supernatant was deposed on a metal surface treated with graphite, and HCCA was electrosprayed on it. This procedure successfully suppressed matrix peaks and was effective in detecting all the target analytes as their protonated species. The results obtained give further confirmation of the effectiveness of the MALDI for detecting drugs and their metabolites in complex biological matrices. The method can be useful as a fast screening procedure to detect the presence of cocaine and metabolites in hair samples.
2009
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2446001
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 32
social impact