This paper shows how the saturation either of the stator or the rotor of a permanent magnet (PM) machine affectS the machine performance, in terms of sensorless rotor position detection capability. An interior permanent magnet (IPM) motor with three rotor flux barriers is considered. The motor geometry is modified so as to achieve a higher iron saturation in the stator and in the rotor. Finite element (FE) simulations are carried out to highlight the effect of such saturation.

Effect of Stator and Rotor Saturation on Sensorless Rotor Position Detection

BIANCHI, NICOLA;FORNASIERO, EMANUELE;BOLOGNANI, SILVERIO
2011

Abstract

This paper shows how the saturation either of the stator or the rotor of a permanent magnet (PM) machine affectS the machine performance, in terms of sensorless rotor position detection capability. An interior permanent magnet (IPM) motor with three rotor flux barriers is considered. The motor geometry is modified so as to achieve a higher iron saturation in the stator and in the rotor. Finite element (FE) simulations are carried out to highlight the effect of such saturation.
2011
Energy Conversion Congress and Exposition (ECCE), 2011 IEEE
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2482729
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 16
social impact