PURPOSE.: To assess synovial microvascularity in finger joints with rheumatoid arthritis (RA) by contrast-enhanced ultrasound (CEUS), distinguishing between cases of active disease and those in remission; to standardize the technique for software analysis. METHODS.: Fifty-two finger joints of RA patients (26 with active disease and 26 in remission) were immersed in water and examined by CEUS using a fixed probe. Signal intensity curves were calculated with the software. RESULTS.: Contrast enhancement was detectable in all 26 patients with active RA (100%), but not in 25 of 26 patients in remission (96%); one of the latter patients (4%) showed minimal enhancement. The method's sensitivity and specificity in distinguishing active disease from remission were 100% and 96%. The grades of synovial enhancement correlated with clinical disease activity and software flow parameters. The peak contrast levels correlated with clinical activity, a peak of 9% representing the cutoff between remission and active disease. CONCLUSIONS.: CEUS with a fixed probe on finger joints immersed in water detected synovial vascularization in RA, producing results suitable for standardized software analysis and avoiding artifacts.

Evaluation of finger joint synovial vascularity in patients with rheumatoid arthritis using contrast-enhanced ultrasound with water immersion and a stabilized probe.

STRAMARE, ROBERTO;PERISSINOTTO, EGLE;FIOCCO, UGO;RUBALTELLI, LEOPOLDO
2012

Abstract

PURPOSE.: To assess synovial microvascularity in finger joints with rheumatoid arthritis (RA) by contrast-enhanced ultrasound (CEUS), distinguishing between cases of active disease and those in remission; to standardize the technique for software analysis. METHODS.: Fifty-two finger joints of RA patients (26 with active disease and 26 in remission) were immersed in water and examined by CEUS using a fixed probe. Signal intensity curves were calculated with the software. RESULTS.: Contrast enhancement was detectable in all 26 patients with active RA (100%), but not in 25 of 26 patients in remission (96%); one of the latter patients (4%) showed minimal enhancement. The method's sensitivity and specificity in distinguishing active disease from remission were 100% and 96%. The grades of synovial enhancement correlated with clinical disease activity and software flow parameters. The peak contrast levels correlated with clinical activity, a peak of 9% representing the cutoff between remission and active disease. CONCLUSIONS.: CEUS with a fixed probe on finger joints immersed in water detected synovial vascularization in RA, producing results suitable for standardized software analysis and avoiding artifacts.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2484977
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 24
social impact