This paper describes the thermal behaviour of a five-phase permanent magnet motor during the post-fault control strategy, considering the open circuit fault of both one and two phases. Proper current control strategies are applied to get proper performance under faulty operating condition. The current of the healthy phases is contextually increased to get a higher average torque, but maintaining the same Joule losses of the healthy case. It is shown that such increase on the average current does not affect the thermal dissipation, and the motor can continue to operate properly also in faulty conditions.
Thermal analysis of a five-phase motor under faulty operations
BIANCHI, NICOLA;FORNASIERO, EMANUELE;BOLOGNANI, SILVERIO
2011
Abstract
This paper describes the thermal behaviour of a five-phase permanent magnet motor during the post-fault control strategy, considering the open circuit fault of both one and two phases. Proper current control strategies are applied to get proper performance under faulty operating condition. The current of the healthy phases is contextually increased to get a higher average torque, but maintaining the same Joule losses of the healthy case. It is shown that such increase on the average current does not affect the thermal dissipation, and the motor can continue to operate properly also in faulty conditions.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
2011_SDEMPED_Thermal_5_Phase_pres_padova_WEB.pdf
accesso aperto
Descrizione: Caricato da Padua@research
Tipologia:
Altro materiale allegato
Licenza:
Pubblico Dominio (CC 1.0)
Dimensione
1.86 MB
Formato
Adobe PDF
|
1.86 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.