The magnetic measurement system of RFX includes a large number of local field probes. A re-calibration after installation has been performed, using the field produced by machine windings,, improving measurement precision. Additional probes have been installed on the shell poloidal gaps. Extensive analyses of RFX magnetic field configuration have been performed: some examples are reported.

Calibration and Operation of the magnetic measurements of RFX

CHITARIN, GIUSEPPE;
1995

Abstract

The magnetic measurement system of RFX includes a large number of local field probes. A re-calibration after installation has been performed, using the field produced by machine windings,, improving measurement precision. Additional probes have been installed on the shell poloidal gaps. Extensive analyses of RFX magnetic field configuration have been performed: some examples are reported.
1995