A design criterion aimed at increasing efficiency without reducing total pressure of Controlled Vortex Design rotor-only tube-axial fans is introduced. The criterion is applied to a production axial fan featuring a 0.44 hub-to-tip ratio and an almost constant swirl velocity distribution at the rotor outlet. In particular, the efficiency improvement is attempted for a fan size characterised by a quite low blade Reynolds number. The criterion is exploited performing experimental tests on each rotor defined by the successive steps suggested in the design guidelines.

Increasing the Efficiency of Rotor-only Axial Fans with Controlled Vortex Design Blades

MASI, MASSIMO;CASTEGNARO, STEFANO;LAZZARETTO, ANDREA
2015

Abstract

A design criterion aimed at increasing efficiency without reducing total pressure of Controlled Vortex Design rotor-only tube-axial fans is introduced. The criterion is applied to a production axial fan featuring a 0.44 hub-to-tip ratio and an almost constant swirl velocity distribution at the rotor outlet. In particular, the efficiency improvement is attempted for a fan size characterised by a quite low blade Reynolds number. The criterion is exploited performing experimental tests on each rotor defined by the successive steps suggested in the design guidelines.
2015
Fan2015. International Conference on Fan Noise, Technology and Numerical Methods
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3157030
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact