Urinary dysfunction can lead to incontinence, with an impact on the quality of life. Severe dysfunction can be overcome surgically by the use of an artificial urinary sphincter. Nonetheless, several complications may result from inappropriate functioning of the prosthesis, in many instances resulting from an unsuitable mechanical action of the device on the urethral tissues. Computational models allow investigation of the mechanical interaction between biological tissues and biomedical devices, representing a potential support for surgical practice and prosthesis design. The development of such computational tools requires experimental data on the mechanics of biological tissues and structures, which are rarely reported in the literature. The aim of this study was to provide a procedure for the mechanical characterization of urethral tissues and structures. The experimental protocol included the morphometric and histological analysis of urethral tissues, the mechanical characterization of the response of tissues to tensile and stress-relaxation tests and evaluation of the behaviour of urethral structures by inflation tests. Results from the preliminary experiments were processed, adopting specific model formulations, and also providing the definition of parameters that characterize the elastic and viscous behaviour of the tissues. Different experimental protocols, leading to a comprehensive set of experimental data, allow for a reciprocal assessment of reliability of the investigation approach.

Experimental investigation of the biomechanics of urethral tissues and structures

NATALI, ARTURO;CARNIEL, EMANUELE LUIGI;FRIGO, ALESSANDRO;PAVAN, PIERO;TODROS, SILVIA;PACHERA, PAOLA;FONTANELLA, CHIARA GIULIA;RUBINI, ALESSANDRO;CAVICCHIOLI, LAURA;DE BENEDICTIS, GIULIA MARIA
2016

Abstract

Urinary dysfunction can lead to incontinence, with an impact on the quality of life. Severe dysfunction can be overcome surgically by the use of an artificial urinary sphincter. Nonetheless, several complications may result from inappropriate functioning of the prosthesis, in many instances resulting from an unsuitable mechanical action of the device on the urethral tissues. Computational models allow investigation of the mechanical interaction between biological tissues and biomedical devices, representing a potential support for surgical practice and prosthesis design. The development of such computational tools requires experimental data on the mechanics of biological tissues and structures, which are rarely reported in the literature. The aim of this study was to provide a procedure for the mechanical characterization of urethral tissues and structures. The experimental protocol included the morphometric and histological analysis of urethral tissues, the mechanical characterization of the response of tissues to tensile and stress-relaxation tests and evaluation of the behaviour of urethral structures by inflation tests. Results from the preliminary experiments were processed, adopting specific model formulations, and also providing the definition of parameters that characterize the elastic and viscous behaviour of the tissues. Different experimental protocols, leading to a comprehensive set of experimental data, allow for a reciprocal assessment of reliability of the investigation approach.
2016
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3187098
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 35
social impact