A procedure for the analysis of total iodine by inductively coupled plasma mass spectrometry (ICP-MS) is proposed, in order to overcome the memory effects and recovery problems highlighted in the literature, which are mainly due to the easy volatilization of iodine during the several analytical steps. The microwave mineralization is performed in aqua regia. After dilution with water and before the injection into the ICP-MS, the solution is added with 0.1 M NH4SCN. Suitable calibration conditions (KIO3 as the iodine standard, 0.69% w/w HNO3 as the medium, and 0.1 M NH4SCN) were individuated. The calibration sensitivity, recovery and limit of detection (LOD) were obtained. This procedure allowed the simultaneous determination of most of the other elements usually analysed by ICP-MS, with the exceptions of Ag, Ba, S, and partly also Pb. The procedure was then used to determine total iodine in selected seaweed samples (Sargassum muticum (Harvey) Suringar, SM, and Undaria pinnatifida (Yendo) Fensholt, UP) collected in six sites around Venice, where no iodine bio-monitoring has been hitherto performed.

A procedure for the quantification of total iodine by inductively coupled plasma mass spectrometry, and its application to the determination of iodine in algae sampled in the lagoon of Venice

BADOCCO, DENIS;DI MARCO, VALERIO;PIOVAN, ANNA;CANIATO, ROSAMARIA;PASTORE, PAOLO
2016

Abstract

A procedure for the analysis of total iodine by inductively coupled plasma mass spectrometry (ICP-MS) is proposed, in order to overcome the memory effects and recovery problems highlighted in the literature, which are mainly due to the easy volatilization of iodine during the several analytical steps. The microwave mineralization is performed in aqua regia. After dilution with water and before the injection into the ICP-MS, the solution is added with 0.1 M NH4SCN. Suitable calibration conditions (KIO3 as the iodine standard, 0.69% w/w HNO3 as the medium, and 0.1 M NH4SCN) were individuated. The calibration sensitivity, recovery and limit of detection (LOD) were obtained. This procedure allowed the simultaneous determination of most of the other elements usually analysed by ICP-MS, with the exceptions of Ag, Ba, S, and partly also Pb. The procedure was then used to determine total iodine in selected seaweed samples (Sargassum muticum (Harvey) Suringar, SM, and Undaria pinnatifida (Yendo) Fensholt, UP) collected in six sites around Venice, where no iodine bio-monitoring has been hitherto performed.
2016
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3205546
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact