AIMS: This study was designed to prospectively evaluate the risk-benefit ratio of implantable cardioverter defibrillator (ICD) therapy in young patients with cardiomyopathies and channelopathies. METHODS AND RESULTS: The study population included 96 consecutive patients [68 men, median age 27 (22-32) years] with cardiomyopathies, such as arrhythmogenic right ventricular cardiomyopathy (n = 35), dilated cardiomyopathy (n = 17), hypertrophic cardiomyopathy (n = 15), Brugada syndrome (n = 14), idiopathic ventricular fibrillation (n = 5), left ventricular noncompaction (n = 4), long-QT syndrome (n = 4) and short-QT syndrome (n = 2), who were 18-35 years old at the time of ICD implantation. During a mean follow-up of 72.6 ± 53.3 months, one patient with end-stage hypertrophic cardiomyopathy died because of acute heart failure, and 11 patients underwent orthotopic heart transplantation. Twenty patients (20.8%) had a total of 38 appropriate ICD interventions (4%/year), and 26 patients (27.1%) experienced a total of 49 adverse ICD-related events (5.4%/year), including 23 inappropriate ICD interventions occurring in nine patients (9.4%) and 26 device-related complications requiring surgical revision occurring in 20 patients (20.8%). Lead failure/fracture requiring lead extraction was the most common complication (n = 9). A threshold for ICD therapy less than 300 ms was associated with a borderline significant lower probability of inappropriate ICD interventions (hazard ratio = 0.2; 95% confidence interval 0.02-1.2; P = 0.07), whereas underweight status was an independent predictor of device-related complications (hazard ratio = 5.4; 95% confidence interval 1.5-19.4; P = 0.01). CONCLUSION: In young patients with cardiomyopathies and channelopathies, ICD therapy provided life-saving protection by effectively terminating life-threatening ventricular arrhythmias. However, because ICD-related adverse events are common, the risk/benefit ratio should be carefully assessed when considering ICD implantation in young people.

Implantable cardioverter defibrillator therapy in young patients with cardiomyopathies and channelopathies: A single Italian centre experience

MIGLIORE, FEDERICO;SILVANO, MARIA;ZORZI, ALESSANDRO;BERTAGLIA, EMANUELE;SICILIANO, MARIACHIARA;LEONI, LOIRA;DE FRANCESCHI, PIETRO;ILICETO, SABINO;CORRADO, DOMENICO
2016

Abstract

AIMS: This study was designed to prospectively evaluate the risk-benefit ratio of implantable cardioverter defibrillator (ICD) therapy in young patients with cardiomyopathies and channelopathies. METHODS AND RESULTS: The study population included 96 consecutive patients [68 men, median age 27 (22-32) years] with cardiomyopathies, such as arrhythmogenic right ventricular cardiomyopathy (n = 35), dilated cardiomyopathy (n = 17), hypertrophic cardiomyopathy (n = 15), Brugada syndrome (n = 14), idiopathic ventricular fibrillation (n = 5), left ventricular noncompaction (n = 4), long-QT syndrome (n = 4) and short-QT syndrome (n = 2), who were 18-35 years old at the time of ICD implantation. During a mean follow-up of 72.6 ± 53.3 months, one patient with end-stage hypertrophic cardiomyopathy died because of acute heart failure, and 11 patients underwent orthotopic heart transplantation. Twenty patients (20.8%) had a total of 38 appropriate ICD interventions (4%/year), and 26 patients (27.1%) experienced a total of 49 adverse ICD-related events (5.4%/year), including 23 inappropriate ICD interventions occurring in nine patients (9.4%) and 26 device-related complications requiring surgical revision occurring in 20 patients (20.8%). Lead failure/fracture requiring lead extraction was the most common complication (n = 9). A threshold for ICD therapy less than 300 ms was associated with a borderline significant lower probability of inappropriate ICD interventions (hazard ratio = 0.2; 95% confidence interval 0.02-1.2; P = 0.07), whereas underweight status was an independent predictor of device-related complications (hazard ratio = 5.4; 95% confidence interval 1.5-19.4; P = 0.01). CONCLUSION: In young patients with cardiomyopathies and channelopathies, ICD therapy provided life-saving protection by effectively terminating life-threatening ventricular arrhythmias. However, because ICD-related adverse events are common, the risk/benefit ratio should be carefully assessed when considering ICD implantation in young people.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3234958
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 16
social impact