Purpose: To evaluate the early effects of dexamethasone (DEX) intravitreal implants in patients with diabetic macular edema (DME). Methods: This was a prospective, single-arm, interventional clinical series. Eighteen patients (18 eyes) with chronic/recalcitrant or naive DME were included. Patients underwent single DEX intravitreal implant. Clinical assessments, including ophthalmologic examination, central retinal thickness (CRT) measurement by spectral-domain optical coherence tomography (SD-OCT) scan, best-corrected visual acuity (BCVA), and intraocular pressure (IOP) were carried out at baseline, 1-3 hours, and then 3, 7, and 30 days after treatment. The main outcome was change in CRT on SD-OCT, while secondary outcome measures included visual acuity (VA) and changes in IOP following implant. Results: Mean CRT significantly decreased from 565 ± 171 µm at baseline to 310 ± 89 µm at end of follow-up (p<0.001), with reduction becoming evident 1-3 hours after injection. Mean BCVA also significantly improved 7 days and 30 days after treatment up to 0.14 logMAR (p<0.05). All patients had a controlled IOP after the injection with only 1/18 eyes having a transient increase in IOP during follow-up. Conclusions: This is the first study showing very early effects of DEX implants on CRT reduction and VA improvement in DME.

Rapid response to dexamethasone intravitreal implant in diabetic macular edema

Campana, Gianluca;
2018

Abstract

Purpose: To evaluate the early effects of dexamethasone (DEX) intravitreal implants in patients with diabetic macular edema (DME). Methods: This was a prospective, single-arm, interventional clinical series. Eighteen patients (18 eyes) with chronic/recalcitrant or naive DME were included. Patients underwent single DEX intravitreal implant. Clinical assessments, including ophthalmologic examination, central retinal thickness (CRT) measurement by spectral-domain optical coherence tomography (SD-OCT) scan, best-corrected visual acuity (BCVA), and intraocular pressure (IOP) were carried out at baseline, 1-3 hours, and then 3, 7, and 30 days after treatment. The main outcome was change in CRT on SD-OCT, while secondary outcome measures included visual acuity (VA) and changes in IOP following implant. Results: Mean CRT significantly decreased from 565 ± 171 µm at baseline to 310 ± 89 µm at end of follow-up (p<0.001), with reduction becoming evident 1-3 hours after injection. Mean BCVA also significantly improved 7 days and 30 days after treatment up to 0.14 logMAR (p<0.05). All patients had a controlled IOP after the injection with only 1/18 eyes having a transient increase in IOP during follow-up. Conclusions: This is the first study showing very early effects of DEX implants on CRT reduction and VA improvement in DME.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3259347
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact