The paper describes the wavefront error measurements of the concave ellipsoidal mirrors M1 and M2, of the concave spherical mirror M0 and of the flat interferential filter IF of the Metis coronagraph. Metis is an inverted occultation coronagraph on board of the ESA Solar Orbiter mission providing a broad-band imaging of the full corona in linearly polarized visible-light (580 - 640 nm) and a narrow-band imaging of the full corona in the ultraviolet Lyman α (121.6 nm). Metis will observe the solar outer atmosphere from a close distance to the Sun as 0.28 A.U. and from up to 35deg out-of-ecliptic. The measurements of wavefront error of the mirrors and of the interferential filter of Metis have been performed in a ISO5 clean room both at component level and at assembly level minimizing, during the integration, the stress introduced by the mechanical hardware. The wavefront error measurements have been performed with a digital interferometer for mirrors M0, M1 and M2 and with a Shack-Hartmann wavefront sensor for the interferential filter.

Optical measurements of the mirrors and of the interferential filter of the Metis coronagraph on Solar Orbiter

Naletto, G.;
2017

Abstract

The paper describes the wavefront error measurements of the concave ellipsoidal mirrors M1 and M2, of the concave spherical mirror M0 and of the flat interferential filter IF of the Metis coronagraph. Metis is an inverted occultation coronagraph on board of the ESA Solar Orbiter mission providing a broad-band imaging of the full corona in linearly polarized visible-light (580 - 640 nm) and a narrow-band imaging of the full corona in the ultraviolet Lyman α (121.6 nm). Metis will observe the solar outer atmosphere from a close distance to the Sun as 0.28 A.U. and from up to 35deg out-of-ecliptic. The measurements of wavefront error of the mirrors and of the interferential filter of Metis have been performed in a ISO5 clean room both at component level and at assembly level minimizing, during the integration, the stress introduced by the mechanical hardware. The wavefront error measurements have been performed with a digital interferometer for mirrors M0, M1 and M2 and with a Shack-Hartmann wavefront sensor for the interferential filter.
2017
Proceedings of SPIE - The International Society for Optical Engineering
9781510612518
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3272492
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact