In the present work, a porosity-based numerical scheme for the Shallow Water Equations is presented. With the aim of accounting for the presence of storage areas, such as gardens, yards and dead zones, and for preferential flow pathways, both an isotropic storage porosity parameter and anisotropic friction are adopted. Particularly, the anisotropic effects due to the building alignments are evaluated defining conveyance porosities along principal directions and using them to express the friction losses in tensor form. The storage and conveyance porosities are evaluated from the geometry of the urban layout at a district scale and then assigned to computational cells rather than to cell sides, thus avoiding oversensitivity to the mesh design. The proposed formulation guarantees the C-property also in presence of wet-dry fronts. Model testing is performed analyzing schematic and idealized urban layouts, and against experimental data as well. The results obtained by the proposed anisotropic scheme are similar to a high-resolution model with resolved buildings, also in the presence of low-friction regimes, meanwhile with a remarkable reduction of the computational times.

Flood inundation modeling in urbanized areas: A mesh-independent porosity approach with anisotropic friction

Viero, Daniele P.;Defina, Andrea;
2019

Abstract

In the present work, a porosity-based numerical scheme for the Shallow Water Equations is presented. With the aim of accounting for the presence of storage areas, such as gardens, yards and dead zones, and for preferential flow pathways, both an isotropic storage porosity parameter and anisotropic friction are adopted. Particularly, the anisotropic effects due to the building alignments are evaluated defining conveyance porosities along principal directions and using them to express the friction losses in tensor form. The storage and conveyance porosities are evaluated from the geometry of the urban layout at a district scale and then assigned to computational cells rather than to cell sides, thus avoiding oversensitivity to the mesh design. The proposed formulation guarantees the C-property also in presence of wet-dry fronts. Model testing is performed analyzing schematic and idealized urban layouts, and against experimental data as well. The results obtained by the proposed anisotropic scheme are similar to a high-resolution model with resolved buildings, also in the presence of low-friction regimes, meanwhile with a remarkable reduction of the computational times.
File in questo prodotto:
File Dimensione Formato  
Ferrari_etal_2019_AWR_AcceptedManuscript_Flood inundation modelling in urbanized areas.pdf

accesso aperto

Descrizione: ACCEPTED VERSION
Tipologia: Postprint (accepted version)
Licenza: Creative commons
Dimensione 3.82 MB
Formato Adobe PDF
3.82 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3288480
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 33
social impact