The Stereo Channel (STC) is a double wide-angle camera developed to be one of the channels of the SIMBIO-SYS instrument onboard of the ESA BepiColombo mission to Mercury. STC main goal is to map in 3D the whole Mercury surface. The geometric and radiometric responses of the STC Proto Flight model have been characterized on-ground during the calibration campaign. The derived responses will be used to calibrate the STC images that will be acquired in flight. The aim is to derive the functions that link the detected signal in digital number to the radiance of the target surface in physical units. The result of the radiometric calibration consists in the determination of well-defined quantities: i) the dark current as a function of the integration time and of the detector temperature, nominally fixed at 268 K; ii) the Read Out Noise, which is associated with the noise signal of the read-out electronic; iii) the Fixed Pattern Noise, which is generated by the different response of each pixel; iv) once these quantities are known, the photon response and the Photo Response Non-uniformity, which represent the variation of the photon-responsivity of a pixel in an array, can be derived. The final result of the radiometric calibration is the relation between the radiance of an accurately known and uniform source, and the digital numbers measured by the detector.

SIMBIO-SYS STC ready for the first light: the radiometric calibration

Slemer, A.;Naletto, G.;
2019

Abstract

The Stereo Channel (STC) is a double wide-angle camera developed to be one of the channels of the SIMBIO-SYS instrument onboard of the ESA BepiColombo mission to Mercury. STC main goal is to map in 3D the whole Mercury surface. The geometric and radiometric responses of the STC Proto Flight model have been characterized on-ground during the calibration campaign. The derived responses will be used to calibrate the STC images that will be acquired in flight. The aim is to derive the functions that link the detected signal in digital number to the radiance of the target surface in physical units. The result of the radiometric calibration consists in the determination of well-defined quantities: i) the dark current as a function of the integration time and of the detector temperature, nominally fixed at 268 K; ii) the Read Out Noise, which is associated with the noise signal of the read-out electronic; iii) the Fixed Pattern Noise, which is generated by the different response of each pixel; iv) once these quantities are known, the photon response and the Photo Response Non-uniformity, which represent the variation of the photon-responsivity of a pixel in an array, can be derived. The final result of the radiometric calibration is the relation between the radiance of an accurately known and uniform source, and the digital numbers measured by the detector.
2019
International Conference on Space Optics
9781510630772
9781510630789
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3310961
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact