BACKGROUND:: Carotid-femoral pulse wave velocity, a predictor of cardiovascular outcome, is conventionally measured using a tonometer sequentially placed upon the carotid and femoral arteries, gated using an electrocardiogram. Leg cuff detection of the femoral pulse removes the need for signal gating, reduces the time required for a single measurement, but gives different pulse wave velocity values to tonometric analysis. A novel algorithm to correct for the transit time and distance related to the additional femoral segment was applied to the cuff-based approach in this study. METHOD:: Eighty-eight individuals were recruited across four centres and carotid-femoral pulse wave velocity measured in triplicate using two operators with both a tonometer-based device and a device using an inflated thigh cuff with and without the use of the novel algorithm. Comparison was made by Bland-Altman and regression analysis. RESULTS:: The unadjusted cuff-based approach gave lower pulse wave velocity values than the tonometer-based approach (6.11 ±â€Š1.27 and 7.02 ±â€Š1.88  m/s, P 

Carotid-femoral pulse wave velocity assessment using novel cuff-based techniques: Comparison with tonometric measurement

Battista F.;
2013

Abstract

BACKGROUND:: Carotid-femoral pulse wave velocity, a predictor of cardiovascular outcome, is conventionally measured using a tonometer sequentially placed upon the carotid and femoral arteries, gated using an electrocardiogram. Leg cuff detection of the femoral pulse removes the need for signal gating, reduces the time required for a single measurement, but gives different pulse wave velocity values to tonometric analysis. A novel algorithm to correct for the transit time and distance related to the additional femoral segment was applied to the cuff-based approach in this study. METHOD:: Eighty-eight individuals were recruited across four centres and carotid-femoral pulse wave velocity measured in triplicate using two operators with both a tonometer-based device and a device using an inflated thigh cuff with and without the use of the novel algorithm. Comparison was made by Bland-Altman and regression analysis. RESULTS:: The unadjusted cuff-based approach gave lower pulse wave velocity values than the tonometer-based approach (6.11 ±â€Š1.27 and 7.02 ±â€Š1.88  m/s, P 
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3382456
Citazioni
  • ???jsp.display-item.citation.pmc??? 25
  • Scopus 71
  • ???jsp.display-item.citation.isi??? 69
social impact