This study evaluated the noise level inside the incubators in a neonatal intensive care unit and identified its sources in order to attempt to reduce it. Although noise is not a proven risk factor as far as the sensory integrity of newborns is concerned, it is certainly an important cause of stress to them and a source of serious and dangerous changes in their behavioral and physiologic states. Noise recorded inside the incubators had two components. The first was background noise from the incubator motors, which varied from 74.2 to 79.9 dB, and was similar to environmental noise. The second source was impulsive events beyond 80 dB. These events were the result of voluntary and involuntary contact with the incubators' Plexiglas surface or to the abrupt opening and closing of their access ports. Considering its decibel levels and frequency, this latter component is undoubtedly an important source of stress to newborns. Moreover, these data reveal the need to train health care personnel on how to reduce such noise by taking more care in the handling of infants.

Evaluation of noise in the neonatal intensive care unit

MAGNAVITA, VINCENZO;ARSLAN, EDOARDO;
1996

Abstract

This study evaluated the noise level inside the incubators in a neonatal intensive care unit and identified its sources in order to attempt to reduce it. Although noise is not a proven risk factor as far as the sensory integrity of newborns is concerned, it is certainly an important cause of stress to them and a source of serious and dangerous changes in their behavioral and physiologic states. Noise recorded inside the incubators had two components. The first was background noise from the incubator motors, which varied from 74.2 to 79.9 dB, and was similar to environmental noise. The second source was impulsive events beyond 80 dB. These events were the result of voluntary and involuntary contact with the incubators' Plexiglas surface or to the abrupt opening and closing of their access ports. Considering its decibel levels and frequency, this latter component is undoubtedly an important source of stress to newborns. Moreover, these data reveal the need to train health care personnel on how to reduce such noise by taking more care in the handling of infants.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/118949
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 33
social impact