A new method for simultaneous determination of underivatized biogenic amines based on the separation by cation-exchange chromatography and suppressed conductivity coupled with mass spectrometry detection has been developed. The method has been applied to the analysis of cadaverine, putrescine, histamine, agmatine, phenethylamine and spermidine in processed meat products. The amines were extracted from muscle tissue with methanesulfonic acid without any additional derivative step or sample clean-up. Biogenic amines were separated by the IonPac CS17 column, a cation-exchange column used with gradient elution, and detection was done by suppressed conductivity and mass spectrometry. Tyramine was simultaneously analysed by using a spectrophotometer (275 nm) before the suppressed conductivity detection. Linearity of response was obtained in the range 0.25–25 µg mL−1. The detection limits ranged from 23 µgL−1 for putrescine to 155 µgL−1 for spermidine (suppressed conductivity) and from 9 µgL−1 for agmatine to 34 µgL−1 for spermidine (MS). Average recoveries from meat samples ranged from 85 to 97% and coefficients of variation ranged from 4.5 to 9.7%. The analysis of biogenic amines in fresh and processed meats (dry-cured, cooked and fermented products) can be used as a quality marker of raw material and for studying the relationship between their changes and the fermentation process involved in dry sausage ripening.

Determination of Biogenic Amines in Fresh and Processed meat by Suppressed IC-MS Using a Cation Exchange Column

PASTORE, PAOLO;
2005

Abstract

A new method for simultaneous determination of underivatized biogenic amines based on the separation by cation-exchange chromatography and suppressed conductivity coupled with mass spectrometry detection has been developed. The method has been applied to the analysis of cadaverine, putrescine, histamine, agmatine, phenethylamine and spermidine in processed meat products. The amines were extracted from muscle tissue with methanesulfonic acid without any additional derivative step or sample clean-up. Biogenic amines were separated by the IonPac CS17 column, a cation-exchange column used with gradient elution, and detection was done by suppressed conductivity and mass spectrometry. Tyramine was simultaneously analysed by using a spectrophotometer (275 nm) before the suppressed conductivity detection. Linearity of response was obtained in the range 0.25–25 µg mL−1. The detection limits ranged from 23 µgL−1 for putrescine to 155 µgL−1 for spermidine (suppressed conductivity) and from 9 µgL−1 for agmatine to 34 µgL−1 for spermidine (MS). Average recoveries from meat samples ranged from 85 to 97% and coefficients of variation ranged from 4.5 to 9.7%. The analysis of biogenic amines in fresh and processed meats (dry-cured, cooked and fermented products) can be used as a quality marker of raw material and for studying the relationship between their changes and the fermentation process involved in dry sausage ripening.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/1426332
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 87
  • ???jsp.display-item.citation.isi??? 79
social impact