The effects of process conditions and the apparatus variables on the granulometric characteristics of a formulation containing a hydrophobic binder (stearic acid), lactose and paracetamol prepared by melt pelletization process were investigated in a 10-litre high shear mixer. The factors under investigation were: impeller speed, massing time, type of impeller blades and presence of the deflector and their reciprocal interactions. Two granule characteristics were analysed: the percentage of aggregates larger than 3000 microm (Y(1)) and the yield of the 2000-microm pellet size fraction (Y(2)). In order to estimate simultaneously the above-mentioned factors, a particular experimental design was adopted, that allowed the reduction of the number of trials from 378 to 35 and took into consideration other uncontrolled factors with the aid of a block variable. Using the postulated model, we found the optimal operating conditions to minimize Y(1) and increase Y(2) by selecting the type of impeller, and by using an impeller speed lower than 300 rpm, a massing time of 8-9 min and by not using the deflector. Finally, the validity of the adopted strategy has been proved with an additional check point.

Melt pelletization in high shear mixer using a hydrophobic melt binder: influence of some apparatus and process variables

FRANCESCHINIS, ERICA
2001

Abstract

The effects of process conditions and the apparatus variables on the granulometric characteristics of a formulation containing a hydrophobic binder (stearic acid), lactose and paracetamol prepared by melt pelletization process were investigated in a 10-litre high shear mixer. The factors under investigation were: impeller speed, massing time, type of impeller blades and presence of the deflector and their reciprocal interactions. Two granule characteristics were analysed: the percentage of aggregates larger than 3000 microm (Y(1)) and the yield of the 2000-microm pellet size fraction (Y(2)). In order to estimate simultaneously the above-mentioned factors, a particular experimental design was adopted, that allowed the reduction of the number of trials from 378 to 35 and took into consideration other uncontrolled factors with the aid of a block variable. Using the postulated model, we found the optimal operating conditions to minimize Y(1) and increase Y(2) by selecting the type of impeller, and by using an impeller speed lower than 300 rpm, a massing time of 8-9 min and by not using the deflector. Finally, the validity of the adopted strategy has been proved with an additional check point.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/154610
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 25
social impact