Abstract: OBJECTIVES: Self-expanding metal stents (SEMS) provide effective palliation in patients with malignant dysphagia, although severe complications and mortality may result. We performed a prospective controlled trial to compare a new self-expanding polyester mesh stent (Polyflex) with SEMS (Ultraflex). METHODS: One hundred one patients with unresectable esophageal carcinoma were randomized to placement of a Polyflex (N = 47) or a partially covered Ultraflex (N = 54) stent. Patients with esophagogastric junction (EGJ) malignancy were excluded. RESULTS: Placement was successful in 46 (98%) patients with the Polyflex and 54 (100%) patients with the Ultraflex stent. In one patient, the Polyflex stent could not be placed. After 1 wk, dysphagia was improved by at least 1 grade in 100% of the Polyflex group and in 94% of the Ultraflex group. Major complications were observed in 48% of the Polyflex group and 33% of the Ultraflex group. Intraprocedural perforation occurred in 1 Polyflex and 1 Ultraflex patient. Two Polyflex patients had postprocedural hemorrhage. Twenty (44%) patients with a Polyflex stent and 18 (33%) with an Ultraflex stent had recurrent dysphagia because of tumor overgrowth, stent migration, hyperplastic granulomatous reaction, or food bolus impaction. Multivariate analysis showed a significantly higher complication rate with Polyflex than with Ultraflex stents (odds ratio 2.3, 95% CI 1.2-4.4). However, median survival was 134 days with Polyflex and 122 days with Ultraflex stents (P = NS). CONCLUSIONS: No difference was seen in palliation of dysphagia between the two stents. Significantly more complications, especially late stent migration, were observed in the Polyflex group.

A randomized prospective comparison of self-expandable plastic stents and partially covered self-expandable metal stents in the palliation of malignant esophageal dysphagia

BATTAGLIA, GIORGIO;
2007

Abstract

Abstract: OBJECTIVES: Self-expanding metal stents (SEMS) provide effective palliation in patients with malignant dysphagia, although severe complications and mortality may result. We performed a prospective controlled trial to compare a new self-expanding polyester mesh stent (Polyflex) with SEMS (Ultraflex). METHODS: One hundred one patients with unresectable esophageal carcinoma were randomized to placement of a Polyflex (N = 47) or a partially covered Ultraflex (N = 54) stent. Patients with esophagogastric junction (EGJ) malignancy were excluded. RESULTS: Placement was successful in 46 (98%) patients with the Polyflex and 54 (100%) patients with the Ultraflex stent. In one patient, the Polyflex stent could not be placed. After 1 wk, dysphagia was improved by at least 1 grade in 100% of the Polyflex group and in 94% of the Ultraflex group. Major complications were observed in 48% of the Polyflex group and 33% of the Ultraflex group. Intraprocedural perforation occurred in 1 Polyflex and 1 Ultraflex patient. Two Polyflex patients had postprocedural hemorrhage. Twenty (44%) patients with a Polyflex stent and 18 (33%) with an Ultraflex stent had recurrent dysphagia because of tumor overgrowth, stent migration, hyperplastic granulomatous reaction, or food bolus impaction. Multivariate analysis showed a significantly higher complication rate with Polyflex than with Ultraflex stents (odds ratio 2.3, 95% CI 1.2-4.4). However, median survival was 134 days with Polyflex and 122 days with Ultraflex stents (P = NS). CONCLUSIONS: No difference was seen in palliation of dysphagia between the two stents. Significantly more complications, especially late stent migration, were observed in the Polyflex group.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/1772561
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 178
  • ???jsp.display-item.citation.isi??? 146
social impact