OBJECTIVE: This study aims to analyse the collective experience of participating European Congenital Heart Surgeons Association centres in the surgical management of complications resulting from trans-catheter closure of atrial septal defects (ASDs). METHODS: The records of all (n=56) patients, aged 3-70 years (median 18 years), who underwent surgery for complications of trans-catheter ASD closure in 19 participating institutions over a 10-year period (1997-2007) were retrospectively reviewed. Risk factors for surgical complications were sought. Surgical outcomes were compared with those reported for primary surgical ASD closure in the European Association of Cardio-thoracic Surgery Congenital Database. RESULTS: A wide range of ASD sizes (5-34mm) and devices of various types and sizes (range 12-60mm) were involved, including 13 devices less than 20mm. Complications leading to surgery included embolisation (n=29), thrombosis/thrombo-embolism/cerebral ischaemia or stroke (n=12), significant residual shunt (n=12), aortic or atrial perforation or erosion (n=9), haemopericardium with tamponade (n=5), aortic or mitral valve injury (n=2) and endocarditis (n=1). Surgery (39 early emergent and 17 late operations) involved device removal, repair of damaged structures and ASD closure. Late operations were needed 12 days to 8 years (median 3 years) after device implantation. There were three hospital deaths (mortality 5.4%). During the same time period, mortality for all 4453 surgical ASD closures reported in the European Association of Cardio-Thoracic Surgery Congenital Database was 0.36% (p=0.001). CONCLUSIONS: Trans-catheter device closure of ASDs, even in cases when small devices are used, can lead to significant complications requiring surgical intervention. Once a complication leading to surgery occurs, mortality is significantly greater than that of primary surgical ASD closure. Major complications can occur late after device placement. Therefore, lifelong follow-up of patients in whom ASDs have been closed by devices is mandatory.

Surgery for complications of trans-catheter closure of atrial septal defects: a multi-institutional study from the European Congenital Heart Surgeons Association

STELLIN, GIOVANNI
2010

Abstract

OBJECTIVE: This study aims to analyse the collective experience of participating European Congenital Heart Surgeons Association centres in the surgical management of complications resulting from trans-catheter closure of atrial septal defects (ASDs). METHODS: The records of all (n=56) patients, aged 3-70 years (median 18 years), who underwent surgery for complications of trans-catheter ASD closure in 19 participating institutions over a 10-year period (1997-2007) were retrospectively reviewed. Risk factors for surgical complications were sought. Surgical outcomes were compared with those reported for primary surgical ASD closure in the European Association of Cardio-thoracic Surgery Congenital Database. RESULTS: A wide range of ASD sizes (5-34mm) and devices of various types and sizes (range 12-60mm) were involved, including 13 devices less than 20mm. Complications leading to surgery included embolisation (n=29), thrombosis/thrombo-embolism/cerebral ischaemia or stroke (n=12), significant residual shunt (n=12), aortic or atrial perforation or erosion (n=9), haemopericardium with tamponade (n=5), aortic or mitral valve injury (n=2) and endocarditis (n=1). Surgery (39 early emergent and 17 late operations) involved device removal, repair of damaged structures and ASD closure. Late operations were needed 12 days to 8 years (median 3 years) after device implantation. There were three hospital deaths (mortality 5.4%). During the same time period, mortality for all 4453 surgical ASD closures reported in the European Association of Cardio-Thoracic Surgery Congenital Database was 0.36% (p=0.001). CONCLUSIONS: Trans-catheter device closure of ASDs, even in cases when small devices are used, can lead to significant complications requiring surgical intervention. Once a complication leading to surgery occurs, mortality is significantly greater than that of primary surgical ASD closure. Major complications can occur late after device placement. Therefore, lifelong follow-up of patients in whom ASDs have been closed by devices is mandatory.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2428102
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 52
social impact