Cardiac allograft vasculopathy (CAV) is the leading cause of morbidity and mortality in heart transplantation (HT). We sought to investigate the role of coronary flow reserve (CFR) by contrast-enhanced transthoracic echocardiography (CE-TTE) in CAV diagnosis. CAV was defined as maximal intimal thickness (MIT) assessed by intravascular ultrasound (IVUS) > or =0.5 mm. CFR was assessed in the left anterior descending coronary artery in 22 HT recipients at 6 +/- 4 years post-HT. CAV was diagnosed in 10 patients (group A), 12 had normal coronaries (group B). The mean MIT was 0.7 +/- 0.1 mm (range 0.03-1.8). MIT was higher in group A (1.16 +/- 0.3 mm vs. 0.34 +/- 0.07 mm, p < 0.0001). CFR was 3.1 +/- 0.8 in all patients and lower in group A (2.5 +/- 0.6 vs. 3.7 +/- 0.3, p < 0.0001). CFR was inversely related with MIT (r =-0.774, p < 0.0001). A cut point of < or =2.9, identified as optimal by receiver operating characteristics analysis was 100% specific and 80% sensitive (PPV = 100%, NPV = 89%, Accuracy = 91%). CFR assessment by CE-TTE is a novel noninvasive diagnostic tool in the detection of CAV defined as MIT > or =0.5 mm. CFR by CE-TTE may reduce the need for routine IVUS in HT.

Coronary Flow Velocity Reserve by Contrast-Enhanced Transthoracic Echocardiography Predicts Maximal Epicardial Intimal Thickening in Cardiac Allograft Vasculopathy

TONA, FRANCESCO;OSTO, ELENA;TARANTINI, GIUSEPPE;NAPODANO, MASSIMO;RAMONDO, ANGELO;GEROSA, GINO;CAFORIO, ALIDA LINDA PATRIZIA;ILICETO, SABINO
2009

Abstract

Cardiac allograft vasculopathy (CAV) is the leading cause of morbidity and mortality in heart transplantation (HT). We sought to investigate the role of coronary flow reserve (CFR) by contrast-enhanced transthoracic echocardiography (CE-TTE) in CAV diagnosis. CAV was defined as maximal intimal thickness (MIT) assessed by intravascular ultrasound (IVUS) > or =0.5 mm. CFR was assessed in the left anterior descending coronary artery in 22 HT recipients at 6 +/- 4 years post-HT. CAV was diagnosed in 10 patients (group A), 12 had normal coronaries (group B). The mean MIT was 0.7 +/- 0.1 mm (range 0.03-1.8). MIT was higher in group A (1.16 +/- 0.3 mm vs. 0.34 +/- 0.07 mm, p < 0.0001). CFR was 3.1 +/- 0.8 in all patients and lower in group A (2.5 +/- 0.6 vs. 3.7 +/- 0.3, p < 0.0001). CFR was inversely related with MIT (r =-0.774, p < 0.0001). A cut point of < or =2.9, identified as optimal by receiver operating characteristics analysis was 100% specific and 80% sensitive (PPV = 100%, NPV = 89%, Accuracy = 91%). CFR assessment by CE-TTE is a novel noninvasive diagnostic tool in the detection of CAV defined as MIT > or =0.5 mm. CFR by CE-TTE may reduce the need for routine IVUS in HT.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2435945
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact