Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The study was carried out in 5 cows exposed to 1.98-3.28 μT of ELFEMFs and in 5 control cows exposed to 0.2-0.7 μT of ELFEMFs. Following haematological and immunologic parameters were measured in both groups: WBC, CD45R, CD6, CD4, CD8, CD21, and CD11B leukocyte antigen expression. Results Some of the haematological and immunologic parameters under investigation were similar in both groups. However, CD8 (T lymphocyte surface antigen) was higher in the exposed group (1.35±0.120 vs 0.50 ± 0.14 × 103/mL). Furthermore, the CD4/CD8 ratio (0.84±0.05 and 2.19±0.16 for exposed and not exposed cows respectively) and circadian rhythm were different between the two groups. Conclusion Exposure to ELFEMFs is responsible of the abnormal temporal variations and distribution of some haematological and immunological parameters in dairy cows. Copyright © 2007 by China CDC.

Effects of exposure to extremely low frequency electro-magnetic fields on circadian rhythms and distribution of some leukocyte differentiation antigens in dairy cows.

STELLETTA, CALOGERO;BASSO, GIUSEPPE;MORGANTE, MASSIMO
2007

Abstract

Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The study was carried out in 5 cows exposed to 1.98-3.28 μT of ELFEMFs and in 5 control cows exposed to 0.2-0.7 μT of ELFEMFs. Following haematological and immunologic parameters were measured in both groups: WBC, CD45R, CD6, CD4, CD8, CD21, and CD11B leukocyte antigen expression. Results Some of the haematological and immunologic parameters under investigation were similar in both groups. However, CD8 (T lymphocyte surface antigen) was higher in the exposed group (1.35±0.120 vs 0.50 ± 0.14 × 103/mL). Furthermore, the CD4/CD8 ratio (0.84±0.05 and 2.19±0.16 for exposed and not exposed cows respectively) and circadian rhythm were different between the two groups. Conclusion Exposure to ELFEMFs is responsible of the abnormal temporal variations and distribution of some haematological and immunological parameters in dairy cows. Copyright © 2007 by China CDC.
2007
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2446608
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact