The erythrocyte sedimentation rate (ESR), now more appropriately referred to as the length of sedimentation reaction in blood (LSRB), remains the most widely used laboratory test for monitoring the course of infections, inflammatory diseases and some types of cancer. Thanks to the several recently developed methods for the measurement of this reaction, the safety and reliability of LSRB testing procedures have improved. The method for LSRB measurement recommended by the International Council for Standardization in Hematology (ICSH) and the National Committee for Clinical Laboratory Standards (NCCLS) is based on the traditional Westergren method, using EDTA-anticoagulated samples. The present paper describes and evaluates a procedure for LSRB measurement with a new manual system, the Microtest 1, which requires only 30 l of blood and is optimal for pediatric use. Microtest 1 results correlated satisfactorily with the ICSH recommended method (r=0.88, 95% CI 0.840.91; y=3.45+0.85x), had no significant bias (2.15, 95% CI 0.324.63) and had an imprecision of less than 7% for the reference range values. In addition, the results obtained with the Microtest 1 in native whole blood were comparable with those obtained with the reference method in K(3)EDTA and sodium citrateanticoagulated specimens; (bias = 1.19, 95% CI 1.78 to 4.16 for K(3)EDTAanticoagulated samples and bias=2.43, 95% CI 0.58 to 5.44 for sodium citrateanticoagulated samples).

Determination of the length of sedimentation reaction (erythrocyte sedimentation rate) in non-anticoagulated blood with the Microtest 1

PIVA, ELISA;PLEBANI, MARIO
2002

Abstract

The erythrocyte sedimentation rate (ESR), now more appropriately referred to as the length of sedimentation reaction in blood (LSRB), remains the most widely used laboratory test for monitoring the course of infections, inflammatory diseases and some types of cancer. Thanks to the several recently developed methods for the measurement of this reaction, the safety and reliability of LSRB testing procedures have improved. The method for LSRB measurement recommended by the International Council for Standardization in Hematology (ICSH) and the National Committee for Clinical Laboratory Standards (NCCLS) is based on the traditional Westergren method, using EDTA-anticoagulated samples. The present paper describes and evaluates a procedure for LSRB measurement with a new manual system, the Microtest 1, which requires only 30 l of blood and is optimal for pediatric use. Microtest 1 results correlated satisfactorily with the ICSH recommended method (r=0.88, 95% CI 0.840.91; y=3.45+0.85x), had no significant bias (2.15, 95% CI 0.324.63) and had an imprecision of less than 7% for the reference range values. In addition, the results obtained with the Microtest 1 in native whole blood were comparable with those obtained with the reference method in K(3)EDTA and sodium citrateanticoagulated specimens; (bias = 1.19, 95% CI 1.78 to 4.16 for K(3)EDTAanticoagulated samples and bias=2.43, 95% CI 0.58 to 5.44 for sodium citrateanticoagulated samples).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2461958
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact