We report on the performances of CsI(Tl) crystals as gamma -ray detectors, compared with standard NaI(Tl). Energy resolution from E-gamma = 122 keV up to E-gamma = 7.6 MeV and light output yield of different CsI(Tl) crystals and read-out configurations (photomultiplier tubes, photodiodes and avalanche photodiodes) have been measured.

CsI(Tl) scintillators as g-ray detectors for the identification of hidden explosives

VIESTI, GIUSEPPE;LUNARDON, MARCELLO;
2001

Abstract

We report on the performances of CsI(Tl) crystals as gamma -ray detectors, compared with standard NaI(Tl). Energy resolution from E-gamma = 122 keV up to E-gamma = 7.6 MeV and light output yield of different CsI(Tl) crystals and read-out configurations (photomultiplier tubes, photodiodes and avalanche photodiodes) have been measured.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2465215