The formation of Cr(VI) in Cr(III) tanned leather, in neutral and alkaline solution, has been demonstrated by means of crossed experiments using different pH buffers, ethylenediaminetetraacetic acid as Cr(III) complexing agent and NaCl solutions. According to the found results the composition of the extracting solution suitable to extract Cr(VI) amount present in leather was pH 4.4 (which is also the tanned leather natural pH) and 5% NaCl (w/v). Interferences coming from coloured compounds have been eliminated with suitable SPE cartridges. A new protocol for the analysis of Cr(VI) based on ion chromatography and a diphenylcarbazide post-column reaction has been implemented. The use of a large volume injection loop (500 microliter) allowed to obtain a very low quantification limit (0.15 mg kg−1) despite the low amount of leather extracted (0.2 g with respect to 2.0 g used by the IUC 18 official method). Evidence of the transient nature of Cr(VI) in leather requires using the external calibration procedure for the correct quantification of the species.

Evidence of Cr(VI) formation during analysis of leather Proposal of an alternative method of analysis through the ion-chromatographic approach and post-column reaction

PASTORE, PAOLO;FAVARO, GABRIELLA;
2004

Abstract

The formation of Cr(VI) in Cr(III) tanned leather, in neutral and alkaline solution, has been demonstrated by means of crossed experiments using different pH buffers, ethylenediaminetetraacetic acid as Cr(III) complexing agent and NaCl solutions. According to the found results the composition of the extracting solution suitable to extract Cr(VI) amount present in leather was pH 4.4 (which is also the tanned leather natural pH) and 5% NaCl (w/v). Interferences coming from coloured compounds have been eliminated with suitable SPE cartridges. A new protocol for the analysis of Cr(VI) based on ion chromatography and a diphenylcarbazide post-column reaction has been implemented. The use of a large volume injection loop (500 microliter) allowed to obtain a very low quantification limit (0.15 mg kg−1) despite the low amount of leather extracted (0.2 g with respect to 2.0 g used by the IUC 18 official method). Evidence of the transient nature of Cr(VI) in leather requires using the external calibration procedure for the correct quantification of the species.
2004
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2465520
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 25
social impact