Abstract 1,3-Butadiene is used in the production of synthetic rubber and is also a widespread environmental pollutant, produced by car exhaust, heating and cigarette smoke. According to IARC it is probably carcinogenic to humans. A method was developed and validated for the quantification in human urine of 1,2-dihydroxybutyl mercapturic acid, a butadiene metabolite for which the American Conference of Governmental Hygienists suggests a biological exposure index of 2500 microg/L. Solid phase extraction was used for analyte extraction and HPLC-MS/MS for detection. The calibration range from 20 to 2500 microg/L required the use of polynomial calibration curves, and the performance of the analytical method was tested according to an international validation guideline. Accuracy was never less than 85%, precision always higher than 15% and the LOD 3.6 microg/L. The method was applied to 33 non-smokers, non-occupationally exposed to butadiene, and gave urinary concentrations between 16 and 599 microg/L.

Quantitative determination of the 1,3-butadiene urinary metabolite 1,2-dihydroxybutyl mercapturic acid by high-performance liquid chromatography/tandem mass spectrometry using polynomial calibration curves

CARRIERI, MARIELLA;BARTOLUCCI, GIOVANNI BATTISTA;LIVIERI, MONICA;
2009

Abstract

Abstract 1,3-Butadiene is used in the production of synthetic rubber and is also a widespread environmental pollutant, produced by car exhaust, heating and cigarette smoke. According to IARC it is probably carcinogenic to humans. A method was developed and validated for the quantification in human urine of 1,2-dihydroxybutyl mercapturic acid, a butadiene metabolite for which the American Conference of Governmental Hygienists suggests a biological exposure index of 2500 microg/L. Solid phase extraction was used for analyte extraction and HPLC-MS/MS for detection. The calibration range from 20 to 2500 microg/L required the use of polynomial calibration curves, and the performance of the analytical method was tested according to an international validation guideline. Accuracy was never less than 85%, precision always higher than 15% and the LOD 3.6 microg/L. The method was applied to 33 non-smokers, non-occupationally exposed to butadiene, and gave urinary concentrations between 16 and 599 microg/L.
2009
File in questo prodotto:
File Dimensione Formato  
Carrieri 20091-s2.0-S1570023209000889-main.pdf

Accesso riservato

Tipologia: Published (Publisher's Version of Record)
Licenza: Accesso privato - non pubblico
Dimensione 276.22 kB
Formato Adobe PDF
276.22 kB Adobe PDF Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2466038
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
  • OpenAlex 10
social impact