Abstract 1,3-Butadiene is used in the production of synthetic rubber and is also a widespread environmental pollutant, produced by car exhaust, heating and cigarette smoke. According to IARC it is probably carcinogenic to humans. A method was developed and validated for the quantification in human urine of 1,2-dihydroxybutyl mercapturic acid, a butadiene metabolite for which the American Conference of Governmental Hygienists suggests a biological exposure index of 2500 microg/L. Solid phase extraction was used for analyte extraction and HPLC-MS/MS for detection. The calibration range from 20 to 2500 microg/L required the use of polynomial calibration curves, and the performance of the analytical method was tested according to an international validation guideline. Accuracy was never less than 85%, precision always higher than 15% and the LOD 3.6 microg/L. The method was applied to 33 non-smokers, non-occupationally exposed to butadiene, and gave urinary concentrations between 16 and 599 microg/L.
Quantitative determination of the 1,3-butadiene urinary metabolite 1,2-dihydroxybutyl mercapturic acid by high-performance liquid chromatography/tandem mass spectrometry using polynomial calibration curves
CARRIERI, MARIELLA;BARTOLUCCI, GIOVANNI BATTISTA;LIVIERI, MONICA;
2009
Abstract
Abstract 1,3-Butadiene is used in the production of synthetic rubber and is also a widespread environmental pollutant, produced by car exhaust, heating and cigarette smoke. According to IARC it is probably carcinogenic to humans. A method was developed and validated for the quantification in human urine of 1,2-dihydroxybutyl mercapturic acid, a butadiene metabolite for which the American Conference of Governmental Hygienists suggests a biological exposure index of 2500 microg/L. Solid phase extraction was used for analyte extraction and HPLC-MS/MS for detection. The calibration range from 20 to 2500 microg/L required the use of polynomial calibration curves, and the performance of the analytical method was tested according to an international validation guideline. Accuracy was never less than 85%, precision always higher than 15% and the LOD 3.6 microg/L. The method was applied to 33 non-smokers, non-occupationally exposed to butadiene, and gave urinary concentrations between 16 and 599 microg/L.| File | Dimensione | Formato | |
|---|---|---|---|
|
Carrieri 20091-s2.0-S1570023209000889-main.pdf
Accesso riservato
Tipologia:
Published (Publisher's Version of Record)
Licenza:
Accesso privato - non pubblico
Dimensione
276.22 kB
Formato
Adobe PDF
|
276.22 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.




