In this paper we discuss strategies for the development of fast photodetectors suitable for operation in the λ > 850 nm near-infrared (NIR) spectral region in the ITER core LIDAR Thomson scattering (TS) system. Detection of this spectral range is necessary if a Nd:YAG laser operating at the fundamental wavelength (λ = 1.06 μm) will be used as the input laser source. Different types of NIR photodetectors are potentially suitable for use in ITER LIDAR TS: the transferred electron (TE) InGaAsP/InP hybrid pho- todiodes and microchannel plate photomultipliers (MCP PMTs), the In(x)Ga(1−x)As MCP image intensifiers and PMTs, and the detectors based on transmission Si photocathodes. But their characteristics of either sensitivity, active area or speed of response, do not match the ITER specifications and all devices require some developmental work. For each of these detector types we review the characteristics of devices presently available and suggest a realistic development strategy suitable to extend their performances to meet the ITER specifications. Finally the expected performance of the ITER LIDAR TS system for different detector choices are compared by calculating the expected signal-to-noise ratio of the measured plasma temperature and density.
Near-infrared detectors for ITER LIDAR Thomson scattering
GIUDICOTTI, LEONARDO;
2011
Abstract
In this paper we discuss strategies for the development of fast photodetectors suitable for operation in the λ > 850 nm near-infrared (NIR) spectral region in the ITER core LIDAR Thomson scattering (TS) system. Detection of this spectral range is necessary if a Nd:YAG laser operating at the fundamental wavelength (λ = 1.06 μm) will be used as the input laser source. Different types of NIR photodetectors are potentially suitable for use in ITER LIDAR TS: the transferred electron (TE) InGaAsP/InP hybrid pho- todiodes and microchannel plate photomultipliers (MCP PMTs), the In(x)Ga(1−x)As MCP image intensifiers and PMTs, and the detectors based on transmission Si photocathodes. But their characteristics of either sensitivity, active area or speed of response, do not match the ITER specifications and all devices require some developmental work. For each of these detector types we review the characteristics of devices presently available and suggest a realistic development strategy suitable to extend their performances to meet the ITER specifications. Finally the expected performance of the ITER LIDAR TS system for different detector choices are compared by calculating the expected signal-to-noise ratio of the measured plasma temperature and density.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.