Scalar and vector magnetic formulations have been applied to solve the current distribution in a 50 Hz direct resistance heating system of ferromagnetic tubes. The scalar formulation driven via an external circuit has been also applied to solve the Time-Harmonic EM part of the problem coupled with the thermal transient: the computed warm up curves have been compared with experimental data. © 2006 IEEE

Coupled magneto-thermal FEM model of direct heating of ferromagnetic bended tubes

DUGHIERO, FABRIZIO;FORZAN, MICHELE
2010

Abstract

Scalar and vector magnetic formulations have been applied to solve the current distribution in a 50 Hz direct resistance heating system of ferromagnetic tubes. The scalar formulation driven via an external circuit has been also applied to solve the Time-Harmonic EM part of the problem coupled with the thermal transient: the computed warm up curves have been compared with experimental data. © 2006 IEEE
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate