OBJECTIVE: We describe a minimally invasive echo-guided placement of the cardiac tube in a ventriculoatrial shunt in a young pregnant woman, in order to avoid any radiological procedure. METHODS: We used a central venous catheter placement kit for percutaneous echo-guided right internal jugular vein puncture located by a 7.5 mHz microlinear probe. Through the catheter, the distal portion of the shunt device was positioned into the internal jugular vein to the right atrium using ultrasound control by a 2.5 to 3.5 mHz probe in a four-chamber transthoracic view. RESULTS: Sonographic guidance in percutaneous placement of a vertebral artery shunt is a safe and fast minimally invasive technique that improves success rates and decreases complications such as incidental puncture of the carotid artery and pneumothorax. The use of a two-dimensional echocardiographic apparatus in a four-chamber transthoracic view is an accurate and simple method to verify the position of the distal tip of the shunt in the mid-right atrium with no risks for the patient. CONCLUSION: The use of these two techniques allows a minimally invasive, safe, accurate, and complete x-ray-free procedure.

Intraventricular astroblastoma. Case report.

DENARO, LUCA;CICCARINO, PIETRO;PERILONGO, GIORGIO;D'AVELLA, DOMENICO
2008

Abstract

OBJECTIVE: We describe a minimally invasive echo-guided placement of the cardiac tube in a ventriculoatrial shunt in a young pregnant woman, in order to avoid any radiological procedure. METHODS: We used a central venous catheter placement kit for percutaneous echo-guided right internal jugular vein puncture located by a 7.5 mHz microlinear probe. Through the catheter, the distal portion of the shunt device was positioned into the internal jugular vein to the right atrium using ultrasound control by a 2.5 to 3.5 mHz probe in a four-chamber transthoracic view. RESULTS: Sonographic guidance in percutaneous placement of a vertebral artery shunt is a safe and fast minimally invasive technique that improves success rates and decreases complications such as incidental puncture of the carotid artery and pneumothorax. The use of a two-dimensional echocardiographic apparatus in a four-chamber transthoracic view is an accurate and simple method to verify the position of the distal tip of the shunt in the mid-right atrium with no risks for the patient. CONCLUSION: The use of these two techniques allows a minimally invasive, safe, accurate, and complete x-ray-free procedure.
2008
1
152
155
4
Internazionale
Sì, ma tipo non specificato
The Pediatrics category covers resources on all aspects of clinical medicine in pediatrics. Pediatric specialties including cardiology, dermatology, gastroenterology, hematology, immunology and infectious diseases, neurology, nutrition, oncology, psychiatry, surgery, tropical medicine, urology, and nephrology are also included. Resources concerned with neonatology and adolescent medicine are also covered.
reserved
Denaro, Luca; Gardiman, M; Calderone, M; Rossetto, M; Ciccarino, Pietro; Giangaspero, F; Perilongo, Giorgio; D'Avella, Domenico
01 CONTRIBUTO IN RIVISTA::01.01 - Articolo in rivista
info:eu-repo/semantics/article
8
262
File in questo prodotto:
File Dimensione Formato  
intraventricular.pdf

Accesso riservato

Tipologia: Published (Publisher's Version of Record)
Licenza: Accesso privato - non pubblico
Dimensione 472.73 kB
Formato Adobe PDF
472.73 kB Adobe PDF Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2491276
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 19
  • OpenAlex 24
social impact