This paper presents an experimental investigation on the dryout during flow boiling of R245fa, R134a and R32 inside a 0.96 mm diameter single circular microchannel. In the present tests, the channel is not electrically heated; instead, the flow boiling is achieved by means of a secondary fluid (water) resulting in a non-uniform distribution of the heat flux along the channel. Since the wall temperature is limited by the temperature of the secondary fluid, the onset of dryout is detected by means of the standard deviation of the temperature readings in the wall. The wall temperature in fact displays larger fluctuations in the zone where dryout occurs, which are related to the presence of the liquid film drying up at the wall with an oscillating process. These temperature fluctuations are detected by means of the standard deviation of the wall temperature. These fluctuations never appear during flow boiling at low vapor qualities; they also disappear in the post-dryout zone. Experimental values of dryout quality measured with the above method are reported in this paper for mass velocity ranging between 100 and 900 kg m-2 s -1, during annular flow. The present data, which covers a wide range of reduced pressure (between 0.05 and 0.34), has been compared against some critical heat flux models available in the literature. Since in the present data the heat flux is not uniform along the channel, each dryout point is characterized by its own boiling story. The actual heat flux profile can be used when comparing with the model by Revellin and Thome [1]. For other models, which are developed for uniformly heated microchannels, the predicted CHF is compared to the average experimental heat flux in the channel.

Investigation of dryout during flow boiling in a single microchannel under non-uniform axial heat flux

DEL COL, DAVIDE;BORTOLIN, STEFANO
2012

Abstract

This paper presents an experimental investigation on the dryout during flow boiling of R245fa, R134a and R32 inside a 0.96 mm diameter single circular microchannel. In the present tests, the channel is not electrically heated; instead, the flow boiling is achieved by means of a secondary fluid (water) resulting in a non-uniform distribution of the heat flux along the channel. Since the wall temperature is limited by the temperature of the secondary fluid, the onset of dryout is detected by means of the standard deviation of the temperature readings in the wall. The wall temperature in fact displays larger fluctuations in the zone where dryout occurs, which are related to the presence of the liquid film drying up at the wall with an oscillating process. These temperature fluctuations are detected by means of the standard deviation of the wall temperature. These fluctuations never appear during flow boiling at low vapor qualities; they also disappear in the post-dryout zone. Experimental values of dryout quality measured with the above method are reported in this paper for mass velocity ranging between 100 and 900 kg m-2 s -1, during annular flow. The present data, which covers a wide range of reduced pressure (between 0.05 and 0.34), has been compared against some critical heat flux models available in the literature. Since in the present data the heat flux is not uniform along the channel, each dryout point is characterized by its own boiling story. The actual heat flux profile can be used when comparing with the model by Revellin and Thome [1]. For other models, which are developed for uniformly heated microchannels, the predicted CHF is compared to the average experimental heat flux in the channel.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2491577
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 36
social impact