The Fe-Mg distribution over the MI and M2 octahedral sites in five natural orthopyroxenes has been determined by single-crystal X-ray diffraction (XRD) and Mossbauer spectroscopy (MS). The results from the two methods are in good agreement for two Fe/Mg intermediate composition samples, provided that the MS data are thickness-corrected. For two Fe-poor and one Al-rich sample, the results diverge ; XRD gives a more ordered Fe-Mg distribution than MS, with up to 0.05 more Fe atoms per formula unit in the M2 position. The thickness effect on MS for ordered orthopyroxene is shown to cause considerable distortion of the spectra, resulting in an underestimate of the degree of ordering. For normally thick absorbers (5 mg Fe/cm2), MS data will allocate approximately 2% too much of total Fe to the M1 position. However, the Fe distribution obtained from MS data can be corrected by extrapolation to zero thickness according to the formula Fe(M1)/Fe(tot)corr = [Fe(M1)/Fe(tot)meas - 0.004085t]/(1 - 0.003031t), where t is the Fe << thickness >> of the absorber in mg Fe/cm2.

Iron Distribution In Ortho-pyroxene - A Comparison of Mossbauer-spectroscopy and X-ray Refinement Results

MOLIN, GIANMARIO;
1992

Abstract

The Fe-Mg distribution over the MI and M2 octahedral sites in five natural orthopyroxenes has been determined by single-crystal X-ray diffraction (XRD) and Mossbauer spectroscopy (MS). The results from the two methods are in good agreement for two Fe/Mg intermediate composition samples, provided that the MS data are thickness-corrected. For two Fe-poor and one Al-rich sample, the results diverge ; XRD gives a more ordered Fe-Mg distribution than MS, with up to 0.05 more Fe atoms per formula unit in the M2 position. The thickness effect on MS for ordered orthopyroxene is shown to cause considerable distortion of the spectra, resulting in an underestimate of the degree of ordering. For normally thick absorbers (5 mg Fe/cm2), MS data will allocate approximately 2% too much of total Fe to the M1 position. However, the Fe distribution obtained from MS data can be corrected by extrapolation to zero thickness according to the formula Fe(M1)/Fe(tot)corr = [Fe(M1)/Fe(tot)meas - 0.004085t]/(1 - 0.003031t), where t is the Fe << thickness >> of the absorber in mg Fe/cm2.
1992
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2506597
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 42
  • OpenAlex ND
social impact