A self-tuning, nonlinear controller was developed to drive portable or implantable micro-pumps for blood glucose control in diabetic subjects. The parameter estimation is based on a recursive least-square algorithm applied to a discrete time simplified mathematical model of the glucose system; the controller, which is integrated with the estimator, uses an extended minimum-variance method. The software was designed to drive a micro-controller wearable unit, operating with different kinds of glucose sensors, in order to perform chemical and biological experimentations. Some strategies were introduced to avoid hypoglycaemia, even tolerating a reduction in control speed and accuracy. The whole system was tested in a simulation study, performed on a mathematical model implemented on a personal computer. The tests were performed while simulating different controller structures and settings, and patient responses. They showed a satisfactory control behaviour, mostly as far as stability and robustness are concerned, in all simulated conditions.

A simulation study on a self-tuning portable controller of blood glucose.

COBELLI, CLAUDIO;
1993

Abstract

A self-tuning, nonlinear controller was developed to drive portable or implantable micro-pumps for blood glucose control in diabetic subjects. The parameter estimation is based on a recursive least-square algorithm applied to a discrete time simplified mathematical model of the glucose system; the controller, which is integrated with the estimator, uses an extended minimum-variance method. The software was designed to drive a micro-controller wearable unit, operating with different kinds of glucose sensors, in order to perform chemical and biological experimentations. Some strategies were introduced to avoid hypoglycaemia, even tolerating a reduction in control speed and accuracy. The whole system was tested in a simulation study, performed on a mathematical model implemented on a personal computer. The tests were performed while simulating different controller structures and settings, and patient responses. They showed a satisfactory control behaviour, mostly as far as stability and robustness are concerned, in all simulated conditions.
1993
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2507666
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 17
  • OpenAlex ND
social impact