BACKGROUND: Few data exist about transcatheter aortic valve implantation (TAVI) in patients with low ejection fraction. The aim of the study was to analyze safety, feasibility, and efficacy of TAVI in patients with severe left ventricular dysfunction. METHODS AND RESULTS: The study sample (384 patients) was divided into 2 groups: group A (50 patients) with left ventricular ejection fraction (LVEF) ≤35%, and group B (334 patients) with LVEF >35%. Clinical, anatomic, and hemodynamic variables, as well as procedural results and follow-up outcomes, were compared between the groups. Procedural success was reached in 88%, with no significant difference between the groups. The incidence of periprosthetic leak >2+/4 after TAVI was higher in group A. All other complications were similar between the 2 groups. Group A showed a significant and early improvement in LVEF (from 27.7±6.0-35.2±11.1 after TAVI; P<0.0001). Thirty-day mortality was 4%; however, this was higher in group A compared with group B (10% versus 3%; P=0.010). Predictors of the cumulative late mortality were congestive heart failure, logistic euroSCORE, and moderate-to-severe periprosthetic leakage after TAVI. Estimated survival by Kaplan Meier at 1 year was, respectively, 69% in group A and 87% in group B (log rank <0.0001). CONCLUSIONS: Transcatheter aortic valve implantation is a safe and effective procedure, even in patients with severe left ventricular dysfunction, leading to a high procedural success rate with an acceptable rate of complications and 30-day mortality. Also in these critically ill patients, TAVI provides clinical amelioration, with early improvement in LVEF.

Transcatheter aortic valve implantation in patients with severe left ventricular dysfunction: immediate and mid-term results, a multicenter study.

FRACCARO, CHIARA;TARANTINI, GIUSEPPE;NAPODANO, MASSIMO;FRIGO, ANNA CHIARA;ILICETO, SABINO;GEROSA, GINO;ISABELLA, GIOVANNI BATTISTA;
2012

Abstract

BACKGROUND: Few data exist about transcatheter aortic valve implantation (TAVI) in patients with low ejection fraction. The aim of the study was to analyze safety, feasibility, and efficacy of TAVI in patients with severe left ventricular dysfunction. METHODS AND RESULTS: The study sample (384 patients) was divided into 2 groups: group A (50 patients) with left ventricular ejection fraction (LVEF) ≤35%, and group B (334 patients) with LVEF >35%. Clinical, anatomic, and hemodynamic variables, as well as procedural results and follow-up outcomes, were compared between the groups. Procedural success was reached in 88%, with no significant difference between the groups. The incidence of periprosthetic leak >2+/4 after TAVI was higher in group A. All other complications were similar between the 2 groups. Group A showed a significant and early improvement in LVEF (from 27.7±6.0-35.2±11.1 after TAVI; P<0.0001). Thirty-day mortality was 4%; however, this was higher in group A compared with group B (10% versus 3%; P=0.010). Predictors of the cumulative late mortality were congestive heart failure, logistic euroSCORE, and moderate-to-severe periprosthetic leakage after TAVI. Estimated survival by Kaplan Meier at 1 year was, respectively, 69% in group A and 87% in group B (log rank <0.0001). CONCLUSIONS: Transcatheter aortic valve implantation is a safe and effective procedure, even in patients with severe left ventricular dysfunction, leading to a high procedural success rate with an acceptable rate of complications and 30-day mortality. Also in these critically ill patients, TAVI provides clinical amelioration, with early improvement in LVEF.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2512680
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 66
  • ???jsp.display-item.citation.isi??? 66
social impact