The mechanical design and construction progress of the CDF silicon vertex detector is described. Results on the location accuracy of the silicon strip detectors are presented and indicate an initial placement uncertainty of less than 10-mu-m. The water and gas cooling system, which is constructed of low mass materials and is used to remove heat from the readout electronics, is briefly described. Measurements of the performance of the silicon strip detectors are also given and show > 98.5% functioning strips for the assembled SVX detector.

Progress In the Construction of the Cdf Silicon Vertex Detector

BISELLO, DARIO;BUSETTO, GIOVANNI;LORETI, MAURIZIO;MARIOTTI, MOSE';
1992

Abstract

The mechanical design and construction progress of the CDF silicon vertex detector is described. Results on the location accuracy of the silicon strip detectors are presented and indicate an initial placement uncertainty of less than 10-mu-m. The water and gas cooling system, which is constructed of low mass materials and is used to remove heat from the readout electronics, is briefly described. Measurements of the performance of the silicon strip detectors are also given and show > 98.5% functioning strips for the assembled SVX detector.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2518465
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact