The radiation response of FOXFETs has been studied for proton, gamma and neutron exposures. The punch-through behaviour, which represents the normal FET operating conditions in Si microstrip detectors, has been found to be much less sensitive to radiation damage than threshold voltage. The device performance has been elucidated by means of two-dimensional simulations. The main radiation effects have been also taken into account in the numerical analysis and separately examined.

Radiation Tolerance of the Foxfet Biasing Scheme For Ac-coupled Si Microstrip Detectors

BISELLO, DARIO;PACCAGNELLA, ALESSANDRO;
1993

Abstract

The radiation response of FOXFETs has been studied for proton, gamma and neutron exposures. The punch-through behaviour, which represents the normal FET operating conditions in Si microstrip detectors, has been found to be much less sensitive to radiation damage than threshold voltage. The device performance has been elucidated by means of two-dimensional simulations. The main radiation effects have been also taken into account in the numerical analysis and separately examined.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2518497
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact