Remarkable technological advances and increased awareness have both contributed to decrease substantially the uncertainty of the analytical phase, so that the manually intensive preanalytical activities currently represent the leading sources of errors in laboratory and transfusion medicine. Among preanalytical errors, misidentification and mistransfusion are still regarded as a considerable problem, posing serious risks for patient health and carrying huge expenses for the healthcare system. As such, a reliable policy of risk management should be readily implemented, developing through a multifaceted approach to prevent or limit the adverse outcomes related to transfusion reactions from blood incompatibility. This strategy encompasses root cause analysis, compliance with accreditation requirements, strict adherence to standard operating procedures, guidelines and recommendations for specimen collection, use of positive identification devices, rejection of potentially misidentified specimens, informatics data entry, query host communication, automated systems for patient identification and sample labeling and an adequate and safe environment.

Identification errors in the blood transfusion laboratory: a still relevant issue for patient safety.

PLEBANI, MARIO
2011

Abstract

Remarkable technological advances and increased awareness have both contributed to decrease substantially the uncertainty of the analytical phase, so that the manually intensive preanalytical activities currently represent the leading sources of errors in laboratory and transfusion medicine. Among preanalytical errors, misidentification and mistransfusion are still regarded as a considerable problem, posing serious risks for patient health and carrying huge expenses for the healthcare system. As such, a reliable policy of risk management should be readily implemented, developing through a multifaceted approach to prevent or limit the adverse outcomes related to transfusion reactions from blood incompatibility. This strategy encompasses root cause analysis, compliance with accreditation requirements, strict adherence to standard operating procedures, guidelines and recommendations for specimen collection, use of positive identification devices, rejection of potentially misidentified specimens, informatics data entry, query host communication, automated systems for patient identification and sample labeling and an adequate and safe environment.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2519860
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 20
social impact