A new test methodology for the analysis of SEE in power MOSFET is presented. It is based on the combined use of an Ion Electron Emission Microscope (IEEM) and an experimental set-up which is able to acquire the drain signals associated to the impacts during the irradiation. The charge generation sensitivity map of a 200 V power MOSFET has been measured. It indicates the areas where the impacting particles generate the maximum charge. This map is strictly correlated with the sensitivity map of the device to SEB.
A new test methodology for an exhaustive study of single-event-effects on power MOSFETs
BISELLO, DARIO;GIUBILATO, PIERO;MATTIAZZO, SERENA;PANTANO, DEVIS;SILVESTRIN, LUCA;
2011
Abstract
A new test methodology for the analysis of SEE in power MOSFET is presented. It is based on the combined use of an Ion Electron Emission Microscope (IEEM) and an experimental set-up which is able to acquire the drain signals associated to the impacts during the irradiation. The charge generation sensitivity map of a 200 V power MOSFET has been measured. It indicates the areas where the impacting particles generate the maximum charge. This map is strictly correlated with the sensitivity map of the device to SEB.File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.