OBJECTIVEdReliability of continuous glucose-monitoring (CGM) sensors is key in several applications. In this work we demonstrate that real-time algorithms can render CGM sensors smarter by reducing their uncertainty and inaccuracy and improving their ability to alert for Q:1 hypo- and hyperglycemic events. RESEARCH DESIGN ANDMETHODSdThe smart CGM (sCGM) sensor concept consists of a commercial CGM sensor whose output enters three software modules, able to work in real time, for denoising, enhancement, and prediction. These three software modules were reQ: 2 cently presented in the CGM literature and here we apply them to the Dexcom SEVEN Plus continuous glucose monitor. We assessed the performance of the sCGM on data collected in two trials, each containing 12 patients with type 1 diabetes. RESULTSdThe denoising module improves the smoothness of the CGM time series by an average of ;57%, the enhancement module reduces the mean absolute relative difference from 15.1 to 10.3%, increases by 12.6% the pairs of values falling in the A-zone of the Clarke error grid, and finally, the prediction module forecasts hypo- and hyperglycemic events an average of 14 min ahead of time. CONCLUSIONSdWe have introduced and implemented the sCGM sensor concept. Analysis of data from 24 patients demonstrates that incorporation of suitable real-time signal processing algorithms for denoising, enhancement, and prediction can significantly improve the performance of CGM applications. This can be of great clinical impact for hypo- and hyperglycemic alert generation as well in artificial pancreas devices

Real-Time Improvement of Continuous Glucose-Monitoring Accuracy - The smart sensor concept

FACCHINETTI, ANDREA;SPARACINO, GIOVANNI;GUERRA, STEFANIA;BRUTTOMESSO, DANIELA;AVOGARO, ANGELO;COBELLI, CLAUDIO;
2013

Abstract

OBJECTIVEdReliability of continuous glucose-monitoring (CGM) sensors is key in several applications. In this work we demonstrate that real-time algorithms can render CGM sensors smarter by reducing their uncertainty and inaccuracy and improving their ability to alert for Q:1 hypo- and hyperglycemic events. RESEARCH DESIGN ANDMETHODSdThe smart CGM (sCGM) sensor concept consists of a commercial CGM sensor whose output enters three software modules, able to work in real time, for denoising, enhancement, and prediction. These three software modules were reQ: 2 cently presented in the CGM literature and here we apply them to the Dexcom SEVEN Plus continuous glucose monitor. We assessed the performance of the sCGM on data collected in two trials, each containing 12 patients with type 1 diabetes. RESULTSdThe denoising module improves the smoothness of the CGM time series by an average of ;57%, the enhancement module reduces the mean absolute relative difference from 15.1 to 10.3%, increases by 12.6% the pairs of values falling in the A-zone of the Clarke error grid, and finally, the prediction module forecasts hypo- and hyperglycemic events an average of 14 min ahead of time. CONCLUSIONSdWe have introduced and implemented the sCGM sensor concept. Analysis of data from 24 patients demonstrates that incorporation of suitable real-time signal processing algorithms for denoising, enhancement, and prediction can significantly improve the performance of CGM applications. This can be of great clinical impact for hypo- and hyperglycemic alert generation as well in artificial pancreas devices
2013
File in questo prodotto:
File Dimensione Formato  
Facchinetti_DiabetesCare_2012_bozze.pdf

accesso aperto

Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 842.18 kB
Formato Adobe PDF
842.18 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2532005
Citazioni
  • ???jsp.display-item.citation.pmc??? 45
  • Scopus 93
  • ???jsp.display-item.citation.isi??? 58
social impact