PURPOSE: To evaluate dose reduction caused by the implantation of an interstitial inflatable and biodegradable balloon device aiming to achieve lower rectal doses with virtual 3D conformal external beam radiation treatment. MATERIALS AND METHODS: An inflatable balloon device was placed, interstitially and under transrectal ultrasound guidance, into the rectal-prostate interspace prior treatment initiation of 26 patients with localized prostate cancer, who elected to be treated with radiotherapy (3D CRT or IMRT). The pre- and post-implant CT imaging data of twenty two patients were collected (44 images) for the purpose of the 3D conformal virtual planning presented herein. RESULTS: The dorsal prostate-ventral rectal wall separation resulted in an average reduction of the rectal V70% by 55.3% (±16.8%), V80% by 64.0% (±17.7%), V90% by 72.0% (±17.1%), and V100% by 82.3% (±24.1%). In parallel, rectal D2ml and D0.1ml were reduced by 15.8% (±11.4%) and 3.9% (±6.4%), respectively. CONCLUSIONS: Insertion of the biodegradable balloon into the prostate-rectum interspace is similar to other published invasive procedures. In this virtual dose distribution analysis, the balloon insertion resulted in a remarkable reduction of rectal volume exposed to high radiation doses. This effect has the potential to keep the rectal dose lower especially when higher than usual prostate dose escalation protocols or hypo-fractionated regimes are used. Further prospective clinical investigations on larger cohorts and more conformal radiation techniques will be necessary to define the clinical advantage of the biodegradable interstitial tissue separation device.

Interstitial biodegradable balloon for reduced rectal dose during prostate radiotherapy: Results of a virtual planning investigation based on the pre- and post-implant imaging data of an international multicenter study

DAL MORO, FABRIZIO;
2013

Abstract

PURPOSE: To evaluate dose reduction caused by the implantation of an interstitial inflatable and biodegradable balloon device aiming to achieve lower rectal doses with virtual 3D conformal external beam radiation treatment. MATERIALS AND METHODS: An inflatable balloon device was placed, interstitially and under transrectal ultrasound guidance, into the rectal-prostate interspace prior treatment initiation of 26 patients with localized prostate cancer, who elected to be treated with radiotherapy (3D CRT or IMRT). The pre- and post-implant CT imaging data of twenty two patients were collected (44 images) for the purpose of the 3D conformal virtual planning presented herein. RESULTS: The dorsal prostate-ventral rectal wall separation resulted in an average reduction of the rectal V70% by 55.3% (±16.8%), V80% by 64.0% (±17.7%), V90% by 72.0% (±17.1%), and V100% by 82.3% (±24.1%). In parallel, rectal D2ml and D0.1ml were reduced by 15.8% (±11.4%) and 3.9% (±6.4%), respectively. CONCLUSIONS: Insertion of the biodegradable balloon into the prostate-rectum interspace is similar to other published invasive procedures. In this virtual dose distribution analysis, the balloon insertion resulted in a remarkable reduction of rectal volume exposed to high radiation doses. This effect has the potential to keep the rectal dose lower especially when higher than usual prostate dose escalation protocols or hypo-fractionated regimes are used. Further prospective clinical investigations on larger cohorts and more conformal radiation techniques will be necessary to define the clinical advantage of the biodegradable interstitial tissue separation device.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2562082
Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 49
social impact