The aim of the present study was to evaluate the importance of a multidisciplinary approach on increasing the response ratio expectation to mandibular advancing device (MAD) therapy in patients with obstructive sleep apnoea syndrome, especially in severe cases. Forty-two mild-to-severe OSAS patients were selected, after comprehensive evaluation by neurologists, otorhinolaryngologists and orthodontists, and treated with a Somnodent® device. Six months later, a polysomnographic exam with the MAD in situ was performed. The paired t-test evaluated the effectiveness of therapy and the results were compared with data from systematic reviews. The average treatment response was statistically significant for the apnoea/hypopnea index (AHI) and oxygen desaturation index and was higher than the outcomes presented in literature. An optimum therapy response (AHI < 5) was observed in 53% of patients (40% in severe OSAS) and a good response (AHI < 10) in 73% of patients (50% in severe OSAS). The Somnodent® device was effective and the multidisciplinary patient selection improved the response ratio compared to that reported by previous systematic reviews.
The impact of a multidisciplinary approach on response rate of mandibular advancing device therapy in patients with obstructive sleep apnoea syndrome.
GRACCO, ANTONIO LUIGI TIBERIO;
2013
Abstract
The aim of the present study was to evaluate the importance of a multidisciplinary approach on increasing the response ratio expectation to mandibular advancing device (MAD) therapy in patients with obstructive sleep apnoea syndrome, especially in severe cases. Forty-two mild-to-severe OSAS patients were selected, after comprehensive evaluation by neurologists, otorhinolaryngologists and orthodontists, and treated with a Somnodent® device. Six months later, a polysomnographic exam with the MAD in situ was performed. The paired t-test evaluated the effectiveness of therapy and the results were compared with data from systematic reviews. The average treatment response was statistically significant for the apnoea/hypopnea index (AHI) and oxygen desaturation index and was higher than the outcomes presented in literature. An optimum therapy response (AHI < 5) was observed in 53% of patients (40% in severe OSAS) and a good response (AHI < 10) in 73% of patients (50% in severe OSAS). The Somnodent® device was effective and the multidisciplinary patient selection improved the response ratio compared to that reported by previous systematic reviews.File | Dimensione | Formato | |
---|---|---|---|
gracco 2013.pdf
accesso aperto
Tipologia:
Published (publisher's version)
Licenza:
Accesso libero
Dimensione
385.75 kB
Formato
Adobe PDF
|
385.75 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.