OBJECTIVE: Drug-eluting stents are more effective in reducing restenosis than bare-metal stents. Paclitaxel-eluting stents (PES) and sirolimus-eluting stents (SES) are the most widely used first-generation drug-eluting stents, but long-term comparative data on these are scant. The aim of the present report is to investigate the 6-year clinical outcomes of PES versus SES in a matched cohort of single-center registry patients. MATERIALS AND METHODS: Data were obtained from the observational, monocentric registry of 632 consecutive patients who underwent percutaneous coronary intervention between September 2002 and September 2005 with PES or SES. We assessed the composite and separate occurrence of the major adverse cardiac events (MACE), including death, nonfatal myocardial infarction, and target lesion revascularization (TLR). RESULTS: After a propensity 1 : 1 matching analysis, baseline clinical, procedural, and angiographic characteristics were well balanced between the two groups. Throughout the 6 years of follow-up, there were no significant differences between PES and SES in terms of MACE (P=0.52), all-cause death (P=0.24), myocardial infarction (P=0.25), stent thrombosis (P=0.38), and TLR (P=0.68). The sensitivity analysis on the total unmatched population confirmed this result, the stent type not being predictive of MACE (PES vs. SES group, hazard ratio 0.97, 95% confidence interval 0.66-1.41, P=0.87) or TLR (PES vs. the SES group, hazard ratio 1.35, 95% confidence interval 0.69-2.64, P=0.38). CONCLUSION: In this 'real-life' registry, PES and SES showed a comparable safety and efficacy profile throughout the 6 years of follow-up. The increase in the rate of TLR was slow and comparable between the two groups, even though the 'late catch-up' phenomenon showed a different temporal pattern between PES and SES.

Six-year clinical outcomes of first-generation drug-eluting stents: a propensity-matched analysis.

TARANTINI, GIUSEPPE;BARIOLI, ALBERTO;FACCHIN, MICHELA;FRIGO, ANNA CHIARA;NAPODANO, MASSIMO;BUJA, PAOLO;D'AMICO, GIANPIERO;ILICETO, SABINO;ISABELLA, GIOVANNI BATTISTA
2013

Abstract

OBJECTIVE: Drug-eluting stents are more effective in reducing restenosis than bare-metal stents. Paclitaxel-eluting stents (PES) and sirolimus-eluting stents (SES) are the most widely used first-generation drug-eluting stents, but long-term comparative data on these are scant. The aim of the present report is to investigate the 6-year clinical outcomes of PES versus SES in a matched cohort of single-center registry patients. MATERIALS AND METHODS: Data were obtained from the observational, monocentric registry of 632 consecutive patients who underwent percutaneous coronary intervention between September 2002 and September 2005 with PES or SES. We assessed the composite and separate occurrence of the major adverse cardiac events (MACE), including death, nonfatal myocardial infarction, and target lesion revascularization (TLR). RESULTS: After a propensity 1 : 1 matching analysis, baseline clinical, procedural, and angiographic characteristics were well balanced between the two groups. Throughout the 6 years of follow-up, there were no significant differences between PES and SES in terms of MACE (P=0.52), all-cause death (P=0.24), myocardial infarction (P=0.25), stent thrombosis (P=0.38), and TLR (P=0.68). The sensitivity analysis on the total unmatched population confirmed this result, the stent type not being predictive of MACE (PES vs. SES group, hazard ratio 0.97, 95% confidence interval 0.66-1.41, P=0.87) or TLR (PES vs. the SES group, hazard ratio 1.35, 95% confidence interval 0.69-2.64, P=0.38). CONCLUSION: In this 'real-life' registry, PES and SES showed a comparable safety and efficacy profile throughout the 6 years of follow-up. The increase in the rate of TLR was slow and comparable between the two groups, even though the 'late catch-up' phenomenon showed a different temporal pattern between PES and SES.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2834364
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact