The interaction position resolution of the segmented HPGe detectors of an AGATA triple cluster detector has been studied through Monte Carlo simulations and in an in-beam experiment. A new method based on measuring the energy resolution of Doppler-corrected γray spectra at two different target to detector distances is described. This gives the two-dimensional position resolution in the plane perpendicular to the direction of the emitted γray. The γray tracking was used to determine the full energy of the γrays and the first interaction point, which is needed for the Doppler correction. Five different heavy-ion induced fusion-evaporation reactions and a reference reaction were selected for the simulations. The results of the simulations show that the method works very well and gives a systematic deviation of <1mm in the FWHM of the interaction position resolution for the γray energy range from 60 keV to 5 MeV. The method was tested with real data from an in-beam measurement using a 30Si beam at 64 MeV on a thin 12C target. Pulse-shape analysis of the digitized detector waveforms and γray tracking was performed to determine the position of the first interaction point, which was used for the Doppler corrections. Results of the dependency of the interaction position resolution on the γray energy and on the energy, axial location and type of the first interaction point, are presented. The FWHM of the interaction position resolution varies roughly linearly as a function of γray energy from 8.5 mm at 250 keV to 4 mm at 1.5 MeV, and has an approximately constant value of about 4 mm in the γray energy range from 1.5 to 4 MeV. © 2011 Elsevier B.V. All rights reserved.

Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors

RECCHIA, FRANCESCO;GOTTARDO, ANDREA;MENGONI, DANIELE;MICHELAGNOLI, CATERINA;
2011

Abstract

The interaction position resolution of the segmented HPGe detectors of an AGATA triple cluster detector has been studied through Monte Carlo simulations and in an in-beam experiment. A new method based on measuring the energy resolution of Doppler-corrected γray spectra at two different target to detector distances is described. This gives the two-dimensional position resolution in the plane perpendicular to the direction of the emitted γray. The γray tracking was used to determine the full energy of the γrays and the first interaction point, which is needed for the Doppler correction. Five different heavy-ion induced fusion-evaporation reactions and a reference reaction were selected for the simulations. The results of the simulations show that the method works very well and gives a systematic deviation of <1mm in the FWHM of the interaction position resolution for the γray energy range from 60 keV to 5 MeV. The method was tested with real data from an in-beam measurement using a 30Si beam at 64 MeV on a thin 12C target. Pulse-shape analysis of the digitized detector waveforms and γray tracking was performed to determine the position of the first interaction point, which was used for the Doppler corrections. Results of the dependency of the interaction position resolution on the γray energy and on the energy, axial location and type of the first interaction point, are presented. The FWHM of the interaction position resolution varies roughly linearly as a function of γray energy from 8.5 mm at 250 keV to 4 mm at 1.5 MeV, and has an approximately constant value of about 4 mm in the γray energy range from 1.5 to 4 MeV. © 2011 Elsevier B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2839076
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 50
  • ???jsp.display-item.citation.isi??? 47
  • OpenAlex ND
social impact