OBJECTIVE: The objective of this study was to determine the accuracy of the A&D BP UB-542 wrist device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension (ESH). METHODS: Device evaluation was carried out in 33 patients. The mean age was 50.9±10.1 years, the mean systolic BP was 141.6±22.8 mmHg (range 92 : 189), the mean diastolic BP was 89.2±11.4 mmHg (range 62 : 120), the mean arm circumference was 28.8±3.2 cm (range 23-35), and the mean wrist circumference was 17.1±1.4 cm (range 14-19.5). The protocol requirements were followed precisely. RESULTS: The device passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated the systolic BP by 1.8±7.2 mmHg and diastolic BP by 1.6±5.7 mmHg. CONCLUSION: These data show that the A&D BP UB-542 wrist device met the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.
Validation of the A&D BP UB-542 wrist device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.
PALATINI, PAOLO
2013
Abstract
OBJECTIVE: The objective of this study was to determine the accuracy of the A&D BP UB-542 wrist device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension (ESH). METHODS: Device evaluation was carried out in 33 patients. The mean age was 50.9±10.1 years, the mean systolic BP was 141.6±22.8 mmHg (range 92 : 189), the mean diastolic BP was 89.2±11.4 mmHg (range 62 : 120), the mean arm circumference was 28.8±3.2 cm (range 23-35), and the mean wrist circumference was 17.1±1.4 cm (range 14-19.5). The protocol requirements were followed precisely. RESULTS: The device passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated the systolic BP by 1.8±7.2 mmHg and diastolic BP by 1.6±5.7 mmHg. CONCLUSION: These data show that the A&D BP UB-542 wrist device met the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.File | Dimensione | Formato | |
---|---|---|---|
Validation of the A&D BP UB-542 wrist device.pdf
accesso aperto
Descrizione: Validation of the A&D BP UB-542 wrist device
Tipologia:
Published (publisher's version)
Licenza:
Accesso libero
Dimensione
65.26 kB
Formato
Adobe PDF
|
65.26 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.