BACKGROUND: Gold standard for spine deformities assessment is X rays, but the procedure bears a risk of exposure. OBJECTIVE: To investigate intra-rater and inter-rater reliability of a pocket compass needle goniometer (IncliMed®, University of Padua) to non-invasively evaluate spine curves in children and adolescents. METHODS: Prospective reliability study in a paediatric population (mean age 12.5 years ± 2.5). Children with spine deformities (Scheuermann's or postural kyphosis, idiopathic scoliosis) and healthy controls were included. Two physician measured spinal curves with the surface goniometer IncliMed® within a temporal range of 10 minutes. Participants were re-tested after a mean of 28 days for the intra-rater study. Agreement limit and coefficient of repeatability were calculated according to the linear regression analysis; the Bland and Altman method was applied to obtain average of differences and standard error of the mean of the differences. RESULTS: One hundred and thirty-nine subjects participated to the inter-rater reliability assessment; 30 to the intra-rater reliability assessment. Inter-observer variability for IncliMed® measurements was ± 11° both for kyphosis and for lordosis. The intra-observer variability for kyphosis and lordosis measurements was ± 11° and ± 12°. CONCLUSIONS: IncliMed® is a reliable, non-invasive tool to screen and monitor spinal curves in paediatric populations.

Goniometric evaluation of the spinal sagittal curves in children and adolescents: A reliability study

DEL FELICE, ALESSANDRA;MASIERO, STEFANO
2016

Abstract

BACKGROUND: Gold standard for spine deformities assessment is X rays, but the procedure bears a risk of exposure. OBJECTIVE: To investigate intra-rater and inter-rater reliability of a pocket compass needle goniometer (IncliMed®, University of Padua) to non-invasively evaluate spine curves in children and adolescents. METHODS: Prospective reliability study in a paediatric population (mean age 12.5 years ± 2.5). Children with spine deformities (Scheuermann's or postural kyphosis, idiopathic scoliosis) and healthy controls were included. Two physician measured spinal curves with the surface goniometer IncliMed® within a temporal range of 10 minutes. Participants were re-tested after a mean of 28 days for the intra-rater study. Agreement limit and coefficient of repeatability were calculated according to the linear regression analysis; the Bland and Altman method was applied to obtain average of differences and standard error of the mean of the differences. RESULTS: One hundred and thirty-nine subjects participated to the inter-rater reliability assessment; 30 to the intra-rater reliability assessment. Inter-observer variability for IncliMed® measurements was ± 11° both for kyphosis and for lordosis. The intra-observer variability for kyphosis and lordosis measurements was ± 11° and ± 12°. CONCLUSIONS: IncliMed® is a reliable, non-invasive tool to screen and monitor spinal curves in paediatric populations.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3211008
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact