The paper presents the analysis of Sodium Nickel chloride batteries in transient operation, and proposes a simple but very precise model to represent both the transient and steady battery behaviours. Hence, the main purpose of this model is to foresee the battery voltage during the most important network services, which require very fast transitions from the battery charge operation to the discharge one. In order to validate the model, several comparisons between experimental measures and model results are shown.

Sodium-nickel chloride battery experimental transient modelling for energy stationary storage

DAMBONE SESSA, SEBASTIAN;BENATO, ROBERTO
2017

Abstract

The paper presents the analysis of Sodium Nickel chloride batteries in transient operation, and proposes a simple but very precise model to represent both the transient and steady battery behaviours. Hence, the main purpose of this model is to foresee the battery voltage during the most important network services, which require very fast transitions from the battery charge operation to the discharge one. In order to validate the model, several comparisons between experimental measures and model results are shown.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3219542
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 19
social impact