High-sensitivity cardiac troponin assays enable cardiac troponin measurement with a high degree of analytical sensitivity and a low level of analytical imprecision at the low measuring range. One of the most important advantages of these new assays is that they allow novel, more rapid approaches for ruling in or ruling out acute myocardial infarctions. The increase in the early diagnostic sensitivity of high-sensitivity cardiac troponin assays comes at the cost of a reduced acute myocardial infarction specificity of the biomarker, because more patients with other causes of acute or chronic myocardial injury without overt myocardial ischaemia are detected than with previous cardiac troponin assays. Increased troponin concentrations that do not fit with the clinical presentation are seen in the daily routine, mainly as a result of a variety of pathologies, and if tested in the same sample, even discrepancies between high-sensitivity cardiac troponin I and troponin T test results may sometimes be found as well. In addition, analytically false-positive test results occasionally may occur since no assay is perfect. In this review, we summarise the biochemical, pathophysiological and analytical background of the work-up for such a clinical setting.

What to do when you question cardiac troponin values

PLEBANI, MARIO;
2017

Abstract

High-sensitivity cardiac troponin assays enable cardiac troponin measurement with a high degree of analytical sensitivity and a low level of analytical imprecision at the low measuring range. One of the most important advantages of these new assays is that they allow novel, more rapid approaches for ruling in or ruling out acute myocardial infarctions. The increase in the early diagnostic sensitivity of high-sensitivity cardiac troponin assays comes at the cost of a reduced acute myocardial infarction specificity of the biomarker, because more patients with other causes of acute or chronic myocardial injury without overt myocardial ischaemia are detected than with previous cardiac troponin assays. Increased troponin concentrations that do not fit with the clinical presentation are seen in the daily routine, mainly as a result of a variety of pathologies, and if tested in the same sample, even discrepancies between high-sensitivity cardiac troponin I and troponin T test results may sometimes be found as well. In addition, analytically false-positive test results occasionally may occur since no assay is perfect. In this review, we summarise the biochemical, pathophysiological and analytical background of the work-up for such a clinical setting.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3228565
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 77
  • ???jsp.display-item.citation.isi??? 68
  • OpenAlex ND
social impact